Programming

Switch G1:

When this switch is open, the photoelectric cell is enabled only

during closing.

When this switch is closed, the photoelectric cell is enabled during

opening and closing.

Switch G2:

When this switch is closed, the automatic closing function is

enabled.

When this switch is open, the automatic closing function is

disabled.

Switch G3:

When this switch is closed, the opening-only command is enabled

- see input terminal 13. The closing command may be given

when the gate is open and not moving, with the button or in

automatic.

When this switch is open, the sequential open-pause-close-open

command is enabled.

Adjustment

T1 TRIMMER

 regulates the operating time of the motors from a

minimum of 2 seconds to a maximum of aproximately 105

seconds.

T2 TRIMMER

 regulates the automatic closing pause time from a

minimum of 2 seconds to a maximum of about 150 seconds.

T3 TRIMMER

 regulates the delay time of the swing which contacts

the rabbet in the closing phase (motor 1), maximum 20 seconds.

Protection

F1

 - T160 mA  Low-voltage input protection.

F2

 - F5 A  220-230 V, 50-60 Hz protection for loads connected

to the mains.

Photoelectric cell

When the photoelectric cell is programmed for closing (switch

G1 is open), if it is intercepted during closing, it interrupts the

gate and reverse its motion from closing to opening when it is

Single-phase motor 1. The motor capacitor is connected

to terminals 1-3.

Single-phase motor 2. The motor capacitor is connected

to terminals 4-6.

220-230 V, 50-60 Hz flashing light.

220-230 V, 50-60 Hz power supply.

Protective ground terminal for connecting yhe main

ground wire.

Functional ground terminal for grounding the control unit’s

metal parts.

Sequential open-stop-close-open button, or opening only.

Normally open contact.

Stop or emergency button. Normally closed contact.

Photoelectric cell. Normally closed contact.

Input common: buttons, photoelectric cell.

24 VAC outputs for powering the photoelectric cell, radio

receiver in container, etc..

12 VDC electric lock.

12 VDC 3 W indicator light.

Antena coaxial cable connection.

DEVICES FOR PROGRAMMING, ADJUSTMENT, AND PROTECTION

freed.

When the photoelectric cell is programmed for closing and

opening (switch G1 closed), if it is intercepted during the closing,

it stops the gate. When the photoelectric cell is freed the gate

will reopen.

If the photoelectric cell is intercepted during the opening phase,

it stops the gate. When the photoelectric cell is freed the gate

will continue to open.

Safety pneumatic frame for anti-entrainment protection

The N.C. contacts of the anti-entrainment pneumatic frame must

be connected in series to the N.C. contact of the stop button on

terminal 14. If the anti-entrainment, anti-crushing pneumatic

frame is intercepted, the opening or closing motion of the gate

stops.

FUNCTION CONTROL LEDS

L1

 - Green LED - Opening command.

L2

 - Red LED - Stop button.

L3

 - Red LED - Photocell.

INDICATOR LIGHT

The indicator light turns on when the gate begins opening.

It remains lit when the gate has stopped and turns off when the

gate begins closing.

ELECTRIC LOCK

The control of a single electric lock has been provided, which is

enabled for approximately 3 seconds when the opening function

starts.

FLASHING LIGHT

The 220-230 V  50-60 Hz flashing light starts functioning

simultaneously with the start of the motor.

CONNECTOR C1

Radio receiver card: if the 10 dip switches for code programming

are present, set the same sequence as set on the transmitter. If

the 10 dip switches are absent the radio receiver is self-learning

and thus the instructions at the end of this handbook must be

followed.

TECHNICAL OPERATING CHARACTERISTICS

- Temperature range: -20 à +70

 °

C.

- Humidity: < 95 % without condensation.

- Voltage: 220-230 V + 10 %.

- Fréquency: 50-60 Hz.

- Max. card  absorption (excluding external charges): 100 mA.

- Micro power cutoff (at max load and min voltage): 20mS.

- Max. power on motor output: 1 CV (736 W).

- Max. load on warning light output: 12 VCC 3 W.

- Max. load on flashing light: 40 W 250 V cosø= 1.

- Available courrent on photocell output: 0,2 A 24 VAC.

- Max. load on electrolock output: 12 VCC 12VA max.

- Radio eceiver connector with supply: 12 V + 15%.

- Degree of box protection: IP 55.

- All inputs must be used as clean contacts, as supply is

generated inside the card and arranged to guarantee double or

reinforced insulation with respect to the live parts.

- All inputs, both functional and safety, are controlled by a

programmable integrated circuit (PAL).

- The stop input (terminal 14 - N.O. contact), other than resetting

the programmable integrated circuit, does not supply the tripping

coil if it remains open; it can therefore, be used to unconditionally

stop the motor in situation of risk to the operator.

Summary of Contents for Plus-2 A

Page 1: ...ARECCHIATURE ELETTRONICHE MONOFASI PLUS 2 A CON MICROPROCESSORE PER IL COMANDO DI DUE MOTORI PER CANCELLI A BATTENTE PLATINES ELECTRONIQUES MONOPHASEES PLUS 2 A AVEC MICROPROCESSEUR POUR LA COMMANDE D...

Page 2: ...arting installation of the product Incorrect installation may cause damage to persons animals or things for which Gi Bi Di cannot be held responsible Before connecting the instrument ensure that the r...

Page 3: ...n 3 mm Check that upstream of the electrical system a differential switch with a threshold of 0 03A is installed Connect the automation to an efficient earthing system as provided by the safety regula...

Page 4: ...direct interven tion and contact qualified technicians only Inobservance of the above may create dangerous conditions Before carrying out any cleaning maintenance or repair operations disconnect the...

Page 5: ...5...

Page 6: ...le gati in serie al contatto N C del pulsante di stop al morsetto 14 se la costa anticonvogliamento ed antischiacciamento viene intercet tata arresta il moto di apertura o chiusura del cancello SPIE L...

Page 7: ...m e pour la fermeture et l ouverture interrupteur G1 en position de marche lorsq elle est intercept e en phase de fermeture elle arr te le mouvement de la grille jusqu ce qu elle ne soit lib r e D s l...

Page 8: ...opening switch G1 closed if it is intercepted during the closing it stops the gate When the photoelectric cell is freed the gate will reopen If the photoelectric cell is intercepted during the opening...

Page 9: ...MMER que regula el tiempo de trabajo de los motores de un m nimo de 2 segundos a un m ximo de 105 segundos aprox T2 TRIMMER que regula el tiempo de pausa del cierre autom tico de un m nimo de 2 segund...

Page 10: ...tram presentes os 10 dip para a programa o do c digo programar a mesma sequ ncia programada no transmissor se os 10 dip n o se encontram presentes o receptor de r dio de tipo com auto aprendimento e p...

Page 11: ...ttiva 92 31 CEE Direttiva 93 68 CEE Compatibilit Elettromagnetica e che sono state applicate le seguenti parti clausole di norme armonizzate EN 60335 1 EN 60204 1 EN 55014 EN 61000 3 2 EN 61000 3 3 EN...

Page 12: ...ne forme un tout avec la machine finale Poggio Rusco le 1 Juin 1998 Administrateur Delegu Tiziano Toselli CE DECLARATION OF CONFORMITY FOR MACHINES Directive 89 392 EEC Attachment II part B PROHIBITI...

Page 13: ...esente declaraci n forme un conjunto nico con la m quina final Poggio Rusco 01 de Junio de 1998 Admistrador Delegado Tiziano Toselli DECLARA O DE CONFORMIDADE PARA M QUINAS Directiva 89 392 CEE Anexo...

Page 14: ...e individuelparradio La m morisation par signal radiodescodesdes metteurs se fait par l activation de chaque meteur Appuyer sur la touche de programmation P1 pour commencer la phase d apprentissage L...

Page 15: ...uefois qu un metteur est mis en m moire les10secondssont remises z ro IL EST POSSIBLE DE MEMORISER 50 CODES DIFFERENTSAUTOTAL S lection des canaux Pourprogrammerlecanalde r ceptiondur ceptorilfaudra a...

Page 16: ...a 24 bits C digos memoriz veis 50 n de canais 1 Tipos de sa da mono est vel Sa da contacto N A no conector Capacidade contacto 0 5 A V i s u a l i z a o funcionamento medianteled vermelho Temp de func...

Reviews: