![GHM DeltaOHM HD2301.0 Operating Manual Download Page 24](http://html1.mh-extra.com/html/ghm/deltaohm-hd2301-0/deltaohm-hd2301-0_operating-manual_2220415024.webp)
HD2301
- 24 -
V1.7
ORD ERI N G COD ES
H D 2 3 0 1 .0
The kit is com posed of t he inst rum ent HD2301.0, 3 1.5V alkaline
bat t eries, operat ing m anual, and case.
The pr obe s m u st be or de r e d
se pa r a t e ly .
P
ROBES COM PLETE W I TH
SI CRAM
M OD ULE
COM BI N ED RELATI VE H UM I D I TY AN D TEM PERATURE PROBES
H P4 7 2 ACR
Com bined probe % RH and t em perat ure, dim ensions Ø26 x 170 m m .
Connect ion cable lengt h 2 m .
H P4 7 3 ACR
Com bined probe % RH and t em perat ure. Dim ensions handle Ø26 x 130
m m , probe Ø14 x 120 m m . Connect ion cable lengt h 2 m .
H P4 7 4 ACR
Com bined probe % RH and t em perat ure. Dim ensions handle Ø26 x 130
m m , probe Ø14 x 215 m m . Connect ion cable lengt h 2 m .
H P4 7 5 ACR
Com bined probe % RH and t em perat ure. Connect ion cable lengt h 2 m .
Handle Ø26 x 110 m m . St ainless st eel st em Ø12 x 560 m m . Point Ø14 x
75 m m .
H P4 7 5 AC1 R
Com bined probe % RH and t em perat ure. Connect ion cable lengt h 2 m .
Handle 80 m m . St ainless st eel st em Ø14 x 480 m m .
H P4 7 7 D CR
Com bined sword probe % RH and t em perat ure. Connect ion cable lengt h
2 m . Handle Ø26 x 110 m m . Probe's st em 18 x 4 m m , lengt h 520 m m .
H P4 7 8 ACR
Com bined probe % RH and t em perat ure. Connect ion cable lengt h 5 m .
St ainless st eel st em Ø14 x 130 m m .
H P4 8 0
% RH and Tem perat ure probe for com pressed air system s. Supplied
com plete with SI CRAM m odule. 2 m connect ion cable. Supplied wit h 15
μ
m AI SI 316 sintered stainless steel filter, m easurem ent cham ber, airflow
control valve and 3 quick connect couplings 1/ 4” ( I talian, Germ an and
Am erican st andard) .
H P4 8 1
% RH and Tem perat ure probe for com pressed air system s. Supplied
com plete with SI CRAM m odule. 2 m connect ion cable. Supplied wit h 15
μ
m AI SI 316 sintered stainless steel filter.
P1
Technopolym er and 34 µm st ainless st eel gr id prot ect ion for probes
Ø26, t hread M24x1.5. Operat ing t em perat ure: - 40…80 ° C.
P2
Technopolym er and 20 µm sint ered PE prot ect ion for probes Ø26, t hread
M24x1.5. Operat ing t em perat ure: - 40…80 ° C.
P3
20 µm sint ered bronze prot ect ion for probes Ø26, t hread M24x1.5.
Operat ing t em perat ur e: - 40…150 ° C.
P4
20 µm sint ered PE prot ect ion for probes Ø26, t hread M24x1.5.
Operat ing t em perat ur e: - 40…80 ° C.
P6
10 µm sint ered st ainless st eel prot ect ion for probes Ø14, t hread M12x1.
Operat ing t em perat ur e: - 40…180 ° C.
P7
20 µm PTFE prot ect ion for probes Ø14, t hread M12x1. Operat ing
t em perat ure: - 40…150 ° C.