Page 1: ...ENG USERS GUIDE WKM335SN...

Page 2: ...nd installing 5 2 2 Connection of the sewing machine 6 2 3 Storage of products in the device 6 2 4 Starting the device 7 2 5 Temperature adjustment 7 3 Maintenance of the appliance 9 3 1 Cleaning the...

Page 3: ...yer of the body is an ecological polyurethane foam The sides of the rack are made of sheet metal and have an insulating layer made of eco logical polyurethane foam The device is designed to be powered...

Page 4: ...3 1 4 SURFACE OF THE DEVICE 1 3 TECHNICAL DATA MODEL TEMPERATURE RANGE C DIMENSIONS LENGTH x DEPTH x HEIGHT mm DISPLAY AREA m2 WKM335SN 1 do 10 C 1960 x 700 x 1985 mm 3 35 Users manual Wall cooling sh...

Page 5: ...pplicable regulations The device is designed to operate at a network voltage in the range of 210 240 V The use of the device outside of the given voltage ranges can lead to irreversible damage which i...

Page 6: ...nd setting the device and before it is put into operation the first wa shing should be carried out The water used for washing should not exceed 40 C with the addition of neutral cleaning agents It is...

Page 7: ...desired temperature is reached Once it has been reached you can start to load the goods When stacking goods on shelves leave space between them to allow air to circulate inside the device Do not place...

Page 8: ...e condensing unit can fluctuate this is related to many factors such as ambient tem perature relative humidity temperature of the products put in and their number etc To adjust the set temperature in...

Page 9: ...8 Diode No 8 when it is lit informs about turning on the fans installed on the device s evapo rator The flashing diode informs about the start delay of the fans from the external switch off or start u...

Page 10: ...f the device This also applies to stainless steel 3 2 CONDENSER CLEANING Version with internal unit Keeping the condenser clean is essential for the proper operation of the refrigeration unit Contamin...

Page 11: ...ay cause injury To remove impurities from the condenser use a soft brush or brush In the case of heavy soiling it is advisable to use a vacuum cleaner compressed air to suck bleed dirt located between...

Page 12: ...ectrical and refrigeration system may be performed by an authorized fitter an authorized service technician 6 If any faults such as sparking electric shock etc occur immediately switch off the device...