1

 

General safety information .............................................................................................. 4

 

Safe operation ......................................................................................................................... 4

 

2

 

Technical Data ................................................................................................................ 6

 

3

 

Mechanical installation .................................................................................................... 7

 

4

 

Electrical installation ..................................................................................................... 11

 

5

 

Limit switch adjustment ................................................................................................. 12

 

6

 

Motor connection .......................................................................................................... 13

 

7

 

Alternative motor connection ......................................................................................... 13

 

8

 

Limit switch connection ................................................................................................. 14

 

9

 

Emergency manual operation (release) ......................................................................... 15

 

10

 

Completing commissioning / inspection ......................................................................... 17

 

11

 

Declaration of incorporation / Declaration of conformity ................................................. 18

 

 

 

 

 

  Symbols 

 

Warning - Potential injury or danger to life! 

 

Warning - Danger to life from electric current! 

 

Note - Important information! 

▶ 

Requirement - Required action! 

Schematic representations are based on product examples. Deviations from delivered 
products are possible. 

Summary of Contents for 10002738 10011

Page 1: ...f Installation Instructions ELEKTROMAT SE 9 30 25 40 ER Model 10002738 10011 en Status 26 03 2021...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...8 Limit switch connection 14 9 Emergency manual operation release 15 10 Completing commissioning inspection 17 11 Declaration of incorporation Declaration of conformity 18 Symbols Warning Potential i...

Page 4: ...d practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe op...

Page 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...

Page 6: ...holding torque 450 Nm Maximum door weight 4000 N Supply voltage 3N 400 V Operating current 1 20 A Operating frequency 50 Hz Power factor cos 0 87 Maximum movement per hour 20 h 1 Class of protection...

Page 7: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Page 8: ...8 Mounting Eight threads are provided for mounting Use at least 2 of these Keys are used to connect to the door shaft Use a key that is at least as long as the hollow shaft 8 x M8x16 BAGAD01001_Z002...

Page 9: ...manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thor...

Page 10: ...t BAGAE01003_Z003 Tighten all connection elements M8 to 25 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE01006_Z002 25 Nm Secure the keys versi...

Page 11: ...are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Inse...

Page 12: ...12 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Page 13: ...13 6 Motor connection M1 Motor X13 Motor plug 7 Alternative motor connection M1 Motor X13 Motor plug...

Page 14: ...14 8 Limit switch connection F10 Thermal contact X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage...

Page 15: ...d to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing t...

Page 16: ...16 Switch on by pulling the red handle Open or close the door by hand Switch off by pulling the green handle...

Page 17: ...ecure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good ele...

Page 18: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The f...

Page 19: ...19...