background image

English

• 

English

• 

Deutsch

• 

Français

• 

Español

Warranty Information ...............................................................................

2

Product Registration ................................................................................

2

Chemical Compatibility ............................................................................

2

Safety Information ...................................................................................

2

Dimensions ..............................................................................................

2

Specifications ..........................................................................................

3

Installation ...............................................................................................

3

Wiring

 ......................................................................................................

6

Battery Installation and Replacement ......................................................

6

Operation .................................................................................................

7

Standard Menu Settings ..........................................................................

7

Security Codes ........................................................................................

8

Totalizer Operation ..................................................................................

9

Automatic Calibration ............................................................................

11

Flow K-Factor ........................................................................................

11

Total K-Factor ........................................................................................

12

Timebase ...............................................................................................

13

Decimal Point Placement ......................................................................

13

Sensitivity ..............................................................................................

14

Speed ....................................................................................................

15

Flow and Totalizer K-Factor Selection ...................................................

15

K-Factor Charts .....................................................................................

16

Troubleshooting .....................................................................................

18

Ordering Information..............................................................................

20

Operating Instructions

Description

Table of Contents

The Signet 8150 Flow Totalizer is a battery-powered instrument capable of providing 

uninterrupted flow and total volume information for 4 years and beyond. The unique 

features of the 8150 include:

•  Easy setup and display selection with 4-button keypad.

•  User selectable security access to prevent unwanted programming changes.

•  Displays flow rate from 0.001 to 9999 engineering units with an auto-ranging 

decimal point.

•  Three totalizers, one permanent and two that are independently resettable.

•  Displays elapsed time between operating periods.

•  Integral mount and panel mount options.

•  3.6 V lithium batteries last 4 years nominal in most applications.

•  Non-volatile memory stores all programming and totalizer values even when 

batteries are removed.

Signet 8150 Flow Totalizer

3-8150.090-1 

Rev. K  9/14 

English

*3-8150.090-1*

Summary of Contents for Signet 8150

Page 1: ...150 Flow Totalizer is a battery powered instrument capable of providing uninterrupted flow and total volume information for 4 years and beyond The unique features of the 8150 include Easy setup and di...

Page 2: ...mical poisoning dry out or mishandling e g broken glass damaged membrane freezing and or extreme temperatures Thank you for purchasing the Signet line of Georg Fischer measurement products If you woul...

Page 3: ...umidity 0 to 95 non condensing Rating NEMA 4X IP65 front panel Shipping Weight 0 5 kg 1 1 lbs Quality Standards CE CUL UL Manufactured under ISO 9001 for Quality ISO 14001 for Environmental Management...

Page 4: ...ng it so the square tab is close to the conduit ports 3 Insert the mounting screw into the conduit base so the head of the screw presses down on the locking ring when tightened 4 Connect sensor wires...

Page 5: ...ied in bold type are required for the installation Other parts are shown for reference only Use 2 conductor shielded cable no more than 30 m 100 ft long Remote Field mount on Pipe Flow Totalizer 3 815...

Page 6: ...d 6 Ext Reset Two 3 6 V lithium thionyl chloride batteries AA size 7400 0011 are installed in the Totalizer NOTE The 8150 will not operate with standard 1 5 V alkaline batteries USE 3 6 V SAFT LS14500...

Page 7: ...uring normal operation Illustrated No flow for 3 hours Operation Standard Menu Settings ENTER 5 sec Function Factory set Description AUTO CALIBRATION No setting See page 11 for detailed information FL...

Page 8: ...lement to the last digit 6 Press the key one time to scroll the flashing digit to 1 7 Press the ENTER key to complete the edit process 8 Press the and keys together to exit the Calibrate menu store th...

Page 9: ...rge volume Total 2 tot2 can be reset only by entering the security code in the calibration menu Total 2 is identified by a flashing display every six seconds Application Use Total 2 for extended measu...

Page 10: ...lizer value will begin flashing The totalizer will automatically reset to 00000000 in 8 seconds While the display is flashing you can cancel the reset by pressing and keys together 5 Press and keys to...

Page 11: ...ted K Factor is less than 0 001 or greater than 999999 Verify the flow rate and start the AutoCAL procedure from step 1 8 Press and keys together to store the new value in the memory The display will...

Page 12: ...o the decimal point 5 Press the key one time to move the decimal point one position to the right 6 Press the ENTER key to return to the menu 7 Press and keys together to exit the menu and return to no...

Page 13: ...ay will not auto range If the decimal is set to tenths the flow rate display will show tenths up to 999 9 then the auto range will switch to whole numbers 1000 to 9999 If the decimal is set to hundred...

Page 14: ...bilized but a sharp change in flow rate is not represented for 60 seconds or longer dotted green line With SPEED at 60 seconds and SENSITIVITY set to 6 the flow rate is stabilized while the sudden shi...

Page 15: ...ss the ENTER key to return to the menu 6 Press and keys together to exit the menu and return to normal operation The display shows Storing for a few seconds then returns to the normal operating displa...

Page 16: ...4 IR4T012 62 979 16 639 1 1 2 IR4T015 46 688 12 335 2 IR4T020 29 459 7 7832 BRONZE TEES ON SCH 40 PIPE 1 BR4T010 104 54 27 619 1 1 4 BR4T012 62 979 16 639 1 1 2 BR4T015 46 688 12 335 2 BR4T020 29 459...

Page 17: ...950 DN 40 SFMT015 43 490 11 490 DN 50 SFMT020 25 908 6 8450 DN 65 SFMT025 18 067 4 7732 DN 80 SFMT030 12 357 3 2648 DN 100 SFMT040 8 0599 2 1294 DN 125 SFMT050 4 4312 1 1707 DN 150 SFMT060 3 2271 0 8...

Page 18: ...ceiving a signal from the flow sensor 1 There is no flow in the pipe 2 Flow sensor is not turning due to blockage or damage 3 Sensor wiring is loose or incorrect In AutoCal the calculated K Factor is...

Page 19: ...19 Signet 8150 Flow Totalizer Notes...

Page 20: ...roof rear cover for panel mount totalizer 3 9000 392 159 000 368 Liquid tight connector kit includes 3 connectors 3 9000 392 1 159 000 839 Liquid tight connector NPT 1 connector 3 9000 392 2 159 000 8...

Reviews: