8
Signet 8150 Flow Totalizer
Changing the Security Code
The security code prevents unauthorized tampering with
calibration and operational settings in the 8150.
The factory standard code is 0-0-0-0. Change the code to any
4-digit number by following these steps:
Example: Change the security code from the factory
standard 0-0-0-0 to custom setting 1-0-0-1
NOTE:
Record and store your security code in a safe place!
1
2 s
2
3
4
5
6
7
8
3x
3x
Enter Security code
1. Hold the ENTER key for 2 seconds, then enter the current
SECURITY CODE.
If working with a new unit, press the ENTER key again.
The display shows the first menu item (AutoCal)
2. Press the ▲ key three times to scroll to Sec Code.
3. Press ► to edit the code.
The leading digit on the display will flash.
4. Press the ▲ key one time to scroll the flashing digit to 1.
5. Press the ► key three times to advance the flashing element
to the last digit.
6. Press the ▲ key one time to scroll the flashing digit to 1.
7. Press the ENTER key to complete the edit process.
8. Press the ▲ and ▼ keys together to exit the
Calibrate menu, store the new settings and return to
normal operation.
Using the Security Code
•
A numerical code (0-0-0-0 to 9-9-9-9) must be entered
before any of the menu selections can be modified.
•
The code is set at 0000 from the factory. To change the
code, see above.
•
To use the factory setting, complete step 1 and then step 8
above.
Example: Enter security code of 1001:
1. Hold the ENTER key for 2 seconds. The display shows
factory standard access code of 0000, with the first zero
flashing.
2. Press the ▲ key one time to scroll the flashing zero to 1.
3. Press the ► key three times to advance the flashing
character to the last place value.
4. Press the ▲ key one time to scroll the flashing zero to 1.
5. Press the ENTER key. The display now shows the first item
in the EDIT MENU.
ENTER
ENTER
Signet Total Flow
Signet Total Flow
Signet Total Flow
Signet Total Flow
Signet Total Flow
1
2
4
5
3
3x
2 s