Operating Instructions MSA 2
Fusion process
15
2.7.2 Cooling time
After the completion of the process, the fusion summary and the
remaining cooling time, if defined in the barcode, are displayed
alternately. Messages are active till the user will press the
STOP/ESC (O) button, to proceed with the next welding.
= 40’
N 150
Remove the external clamp only when the cooling time is expired!
Danger of burning!
The fitting area is hot! Pay attention during the removal of the cables.
When the cooling time is going to finish or finished, an acoustic
signal alerts the user the process is near to complete.
2.8
Welding check
The electro-fusion fittings are equipped with pins, giving evidence of
the heating process occurred: double check if they are sticking out.
This indication is not enough to ensure the quality of the welding, but
just confirming the heating has occurred! Therefore please follow the
instructions of the fitting manufacturer.
Warning
Danger
Attention