Fusion process
Operating Instructions MSA 2
12
2.5
Enter fusion data
After that, the user can insert the fusion parameters:
•
Either reading the barcode information with the scanner,
•
or, if the barcode cannot be read with a scanner for any
reason, entering manually fusion time and voltage by
pressing the START/OK ( I ) button to go in “edit” mode
and then using (
) and (
) to select the required digits
and (
) (
) to change field. Once the values are entered,
must be pushed START/OK ( I ).
At this stage, to ensure a reliable jointing, pipes and fitting have
to be already prepared: pipes must have been scraped, cleaned,
aligned following the instructions of the fitting manufacturers.
If fusion parameters are not acquired, there might be several
reasons:
•
The barcode reader may be operated in a wrong way: try to
put it closer to the barcode
•
The barcode may be damaged
•
The data are not the expected ones (prolonged tone
generated by the machine): the barcode read does not
contain fusion parameters
As soon as the data are correctly read from the barcode, the
machine confirms with a double acoustic tone and show on the
display a summary of the captured fusion parameters: time,
voltage and expected coil resistance.
t = 0040s
Vo= 39.5V
R = 07.45
Ω
12/06/12 15:50
25°C
Summary of Contents for MSA 2.0
Page 2: ......
Page 27: ...Operating Instructions MSA 2 Accident Prevention 25...
Page 28: ...Bedienungsanleitung GF Piping Systems MSA 2 0 MSA 2 1 Polyvalentes Elektroschweissger t...
Page 30: ...Operating Instructions MSA 2 28 8 5 Ger t ffnen 51 8 6 Arbeitssicherheit 52 8 7 Entsorgung 52...
Page 55: ...Operating Instructions MSA 2 Unfallschutz Vorschriften 53...
Page 56: ...Manuel d utilisation GF Piping Systems MSA 2 0 MSA 2 1 Unit d lectrosoudage polyvalente...
Page 85: ......
Page 86: ......
Page 87: ......