32
EN
Action
Carry out backwash
Repeat backwash several
times
Unscrew wastewater connec-
tion (6) and clean vent tube (5)
outside
If the fault cannot be remedied by following these tips, contact our after-sales service department.
Troubleshooting
Operation
We recommend programming the filter so that
the device is backwashed at least once a month to
prevent foreign particles from adhering to the filter
element (more frequently for higher levels of soiling;
factory setting every 7 days).
Setting the backwash interval
see Starting the unit
Manual backwashing
Unplugging and plugging in the device can back-
wash it at any time.
Display
displays the time until the next backwashing.
Cleaning
Clean plastic parts with a soft, damp cloth only;
do not use solvents, detergents, or acidic cleaning
agents.
Maintenance
All technical equipment requires regular mainte-
nance. This should always be carried out by qualified
staff, who will also replace any worn parts.
The filter needs regular check of tightness, as well
a carry out backwash every second month.
Warranty
If the unit malfunctions during the warranty
period, please contact your contract partner, the
installation company and quote the model type
and the production number (see specifications or
the type plate on unit).
Fault
Water pressure dropped consid-
erably in network
Flushing water outlet does not
close
Cause
Dirty filter element
Backwash element does not re-
ach the end position due to large
particles of dirt
Scaling at the vent tube (5)