Rod locking
6
Assembly of Slimdrive SL and Slimdrive SLT product families (without RC2 variants)
X
Tighten the fixing screws (7) of the housing fasteners so that the
locking device can be moved in the track with as little play
as possible.
X
Connect the locking device and control unit with the rod locking
cable in accordance with the wiring diagram.
X
Lay the cables (8) so that its cannot be damaged by the rod locking
during locking and unlocking.
4.3 Aligning the locking device
X
Close one door leaf carefully.
X
Align the locking device and the door leaf to each other so that the
head part of the locking bolt (9) moves centred into the T-groove
of the dead bolt (1) (distance between upper edge of door rail and
lower edge of housing profile ~4.5 mm).
It must be possible to close the door leaf without noise. If a noise can
be heard when the vertical rod moves into the dead bolt, the vertical
rod has to be adjusted (see Chapter 7).
X
Fasten the locking device with the fixing screws (7) of the housing
fasteners to the track (7 Nm ± 0.5 Nm).
X
Open the door leaf and carry out the steps as described above at
the other door leaf.
X
Check whether the locking bolts (10) engage in the manual locking
device (3) in the closed position of the door leaves.
X
If not, correct the position of the door leaves in the closed position
so that the locking bolts engage in the manual locking device
X
Repeat the aligning work as described above.
X
Tighten the suspension bolts.