SECULOGIC TZ320
17
Terminal diagram
Unlocking through BMA, GMA or RWA
6.4
A local emergency button is required
BMA / GMA / RWA
NC
COM
TZ320
X106 (orange terminal strip)
Input 1 (short-term release)
9
2
24 V DC
Input 3 (fire alarm system)
53
52
Input short-term release)
2 (
Set input 3 of the TZ320 to:
Fire detection system (factory setting)
à
Low active (NC contact)
à
Before connecting, set input to “deactivated”, as an alarm is otherwise triggered. If the BMA, GMA or RWA system
contains an NO contact for unlocking, set the input to “High Active”.
Key switch SCT221/SCT to temporary unlocking
6.5
Brief unlocking input
24 V DC
(orange terminal strip)
SCT No. 024467 UP AS500
SCT No. 120503 AP AS500
SCT221 No . 024467 without PHZ UP
SCT221 No . 024467 without PHZ AP
SCT221 No . 024467 with PHZ UP
SCT221 No . 024467 with PHZ AP
Key switch SCT320 for external control unlocking, locking, temporary
6.6
unlocking and acknowledging alarms
X105
24 V DC
Lock SCT, KFZ, acknowledge
Unlock SCT, acknowledge
Closed on right
Closed on left
No. 115937, UP Jung AS500, WW
No. 094170, UP Jung LS990, stainless steel
No. 094012, UP Jung GIRA E2, pure white