0
Voltage [V DC]
24 ±25% SELV
max. residual ripple Uss [%]
20
Continuous duty [%]
30
Power consumption [W]
22
Current consumption [A]
0.9
Ambient temperature [°C]
-5 / +70
Protection class [IP] / rating
42 / III
Application area
dry rooms
Voltage [V AC]
230 ±10%
Frequency [Hz]
50
Continuous duty [%]
30
Operating time [min.]
4
Power consumption [W]
30
Current consumption [A]
0.13
Ambient temperature [°C]
-5 / +70
Protection class [IP] / rating
42 / II
Application area
dry rooms
2
Maintenance
GEZE’s recommendation is for at least one service per year. This should be carried out by
qualified personnel. The service should include a check of correct function, mechanical
condition and the supply cable.
3
Technical data
Mechanical data E740
Pushing force [N]
250
Pulling force [N]
300
Pushing speed [mm/s]
7
End position cut-off extended
integrated displacement transducer
End position cut-off retracted
Current consumption
Overload switch-off
via current consumption
Weight [kg]
approx. 1,7
Stroke length [mm] can be selected from rotary switch 100/200/300/400
Subject to technical changes!
Electrical data E740 - 24 V
Electrical data E740 - 230 V
When the window closes the end position cut-off works automatically. The pulling force
against the seals is over 300 N.