Stroke/end position setting
E 212 R1 / E 212 R / E 212
GB 10
7
Stroke/end position setting
-
+
1
LED (green)
2
Setting screw stroke
The stroke is set to 52 mm in the factory.
X
X
Set and check the stroke according to fitting stroke
Setting value = Fitting stroke – 2 mm
Example OL90: Setting stroke 54 mm = Setting value drive 52 mm
When adjusting the limit switch make sure that it is switched off correctly
and the green LED on the drive has gone out.
The setting must be checked and safeguarded by means of a test run.
Summary of Contents for E 212
Page 11: ...E 212 R1 E 212 R E 212 DE 11...
Page 23: ...A III 1 GND 24 V DC 3 2 24 V DC GND E 212 3 x 1 5 mm2 24 V DC...
Page 24: ......
Page 25: ......
Page 26: ...E 212 R1 E 212 R E 212 Notizen Notes...