GB 9
Technical data
E 212 R1 / E 212 R / E 212
6
Technical data
Main dimensions
Mechanical data
E212 R1 230 V /
E 212 R 230 V AC
E 212 /24 V DC
Max. tensile force and force of pressure [N] 1500
1500
Stroke speed [mm/s]
1.5
1.5
End position cut-off
Limit switch
Limit switch
Weight [kg]
1.2
1.2
Max. stroke length [mm]
70 mm, adjustable
70 mm, adjustable
Setting range, stroke [mm]
42-70
42-70
Electrical data
Voltage
230 V AC +/- 10%
24 V DC +/- 25%
Frequency [Hz]
50
---
Switch-on duration [%], S3
25
25
Short-term operation [min]
3
3
Power consumption [W]
50
29
Current consumption [A], approx.
0.2
1.2
Ambient temperature [°C]
-20/+60
-20/+60
Enclosure rating [IP] / protection type
IP 42 / I
IP 42 / III
Type of connection
Fixed connection
Fixed connection
Max. connection cross-section [mm]
1.5
2.5
Supply cable
E 212 R1: 4 x 1.5 mm
2
E 212 R: 5 x 1.5 mm²
with PE
3 x 1.5 mm
2
without PE
Area of application
dry rooms
dry rooms
Subject to technical modifications!
The end position cut-off over the limit switch must be set properly.