The timed thermostat can be set with 2 different control modes:
•
Master:
the timed thermostat sets the type, operating mode or setpoint of the devices
configured as Slaves (e.g. the Easy flush-mounting thermostats GW1x765H). In the first case
(mode), the thermostats use the setpoints set locally. The fixed temperature setpoint can be
temporarily forced (max. variation ±3°C), but the operating mode cannot be altered. The forced
setpoint will remain valid until the master device sends a new operating mode. In the second
case (set-points), the thermostats use the setpoint received from the Master device (which can
always be altered locally with a max. variation of ±3°C).
•
Autonomous:
the timed thermostat type and operating mode can be set locally. Operation is
not dependent on any other device. In the autonomous control mode, you can alter the setpoint
as you wish, and enable the timed thermostat to receive remote commands to modify the mode
setpoint (OFF/Economy/Pre-comfort/Comfort) and set the type (Heating/Cooling) received from
other devices such as a push-button or the Easy GSM remote control.
The timed thermostat has 5 different operating modes:
• AUTOMATIC
• ECONOMY
• PRE-COMFORT
• COMFORT
• OFF - ANTIFREEZE/HIGH TEMPERATURE PROTECTION
In any control mode (autonomous or master), to switch from one HVAC mode (economy, pre-
comfort, comfort, off) to another, use the
button key: each time it is pressed, the
corresponding setpoint is shown (flashing) for a moment.
In
automatic operation mode
, the timed thermostat uses a
program that can be differentiated for each day of the week.
The display shows the word AUTO, the detected room
temperature, and the symbol of the setpoint for the current
quarter hour period. In the hourly profile, the column relating
to the current hour flashes, showing the current setpoint.
In the
economy, pre-comfort and comfort operating modes
,
the timed thermostat always uses the corresponding
temperature set-points.
The display shows the detected room temperature and the
,
or
symbol.
Control modes
Operating modes