5.6.1.4. Moving
parts
Warning!
Cooling fans are supplied with inlet and outlet ports uncovered; take care
when fitting ducting to these ports. Fans should never be run with ports uncovered; this
may cause injury by ejecting loose objects at high speed or trapping the hands.
5.6.1.5. High
temperatures
Warning!
Hot surfaces and electrical energy can cause fires to break out. High
temperatures occur inside the UV dryer. Allow the dryer to cool from full power for five
minutes before attempting to remove or open any lamp head, then proceed with caution.
Operators should always be vigilant. NEVER use flammable solvents near the UV dryers
when the lamps are in operation. If a fire should break out, follow the procedure posted for
the building.
Only fire extinguishers of the dry powder type should be used on this equipment.
5.6.1.6. High
voltages
Warning!
UV lamps operate at high voltages, typically 450V to 1400V depending on
lamp type; additionally when striking the lamps, ignitor circuitry will generate pulses in
excess of 2kV. These voltages present a possible danger of electric shock or fire.
Do not mount other equipment so that it could interfere with the safe operation of the
system. When testing or troubleshooting, all safety interlocks shall be in place and cables
left intact.
5.6.2. Misuse and prohibited usages
The
e-Brick
is designed solely intended for powering specific GEW UV and IR dryers. All
other applications are prohibited, unless prior written consent has been obtained from GEW.
5.7.
Fault identification and repair
Warning!
There are no user serviceable parts inside the
e-Brick
; do not remove covers
under any circumstances. Please note that if factory security seals are broken, the warranty is
void. Refer to GEW or your local agent for service.
5.8.
Personal Protective Equipment
Due to their weight, it is advisable to wear safety shoes when installing
e-Brick
products.
Warning!
Other protective equipment may be required while installing an
e-Brick
system. If
necessary, consult your local Health and Safety representative for advice.
5.9. Training
required
Although designed for ease of installation, GEW systems should be installed and commissioned by
GEW service technicians. Alternatively some customers and OEMs have their own GEW trained
personnel. Please contact GEW Customer Service for information on installation training for your
GEW UV system.
GEW UV
e-Brick
installation and operating manual