8
9
Description of functions
• Green LED lights up - the detector has been
connected correctly
Fig. 2A
.
• Orange LED lights up - the detector is indicating that
there is a fault
Fig. 2B
.
Maintenance
The detector can be fully tested using the test button
(also the mute button)
Fig. 2E
. Perform a test at least
once a month. Press and hold down the test button until
the red and orange LEDs flash and the audible alarm
sounds intermittently (approx. 85 dB). It is not sufficient
to simply test operability by using a gas fire device, such
as a gas lighter or a gas stove.
• If the red LED flashes and there is an intermittent
audible alarm, this means that the device has
detected gas
Fig. 2C
, please refer to the section
What to do in the event of an alarm
. The alarm
output on the back of the device will be
activated
Fig. 3A
.
Cleaning the detector
When necessary (usually about twice a year), wipe the
device with a clean, dry cloth and clean the outside
with a vacuum cleaner. The FlammEx gas detector
automatically performs a self-test. If there is a fault,
the orange LED
Fig. 2B
will flash continuously. This
indicates that the detector needs to be replaced.
Green LED
(Fig. 2A)
Orange LED
(Fig. 2B)
Red LED
(Fig. 2C)
Alarm
Description
Constantly lit
off
off
off
Normal operation
Flashes, for
approx. 10 mins.
off
off
off
Warm-up phase
Constantly lit
off
flashing
intermittent alarm
Alarm, please
refer to
What to
do in the event of
an alarm
Constantly lit
Constantly lit
off
off
Fault, change
device
Constantly lit
flashing
flashing
intermittent alarm
Test alarm
Constantly lit
off
flashing
short beep every
45 sec.
Alarm has been
silenced