1 General 

guidelines 

The purpose of these instructions is to explain to the user how to use the 
GS 43 sealer safely and correctly. 

Anyone whose work involves using the sealer must be familiar with these 
instructions and the safety regulations. 

These instructions must always be available to personnel, to prevent incorrect 
use of the sealer and to ensure trouble-free operation. 

Copyright 

These instructions may only be given to third parties with the written consent 
of GETINGE. All documents are protected by copyright. 

The passing-on and copying of documents, including extracts and the 
communication or use for gain of their contents is not permitted, except by 
express consent. Infringements are punishable and will lead to claims for 
damages. We reserve all rights to exercise the provisions of commercial 
copyright law. 

Warranty and liability 

We accept liability within the terms of the stated warranty obligations for errors 
and omissions, to the exclusion of further claims. 

We reserve the right to make technical changes to the sealer covered by this 
instruction manual, for the purpose of further development. 

We accept no liability for damage and operational disturbances arising from 
incorrect operation, failure to observe these instructions, or improper repairs. 
Only original spare parts and accessories approved by GETINGE may be 
used. 

GETINGE accepts no liability for damage resulting from the use of non-
approved spare parts and accessories. 

The drawings and graphics are not to scale. 

 

2

Summary of Contents for GS 43

Page 1: ...er 4 2 5 Contamination of the sterilised goods Danger of patient infection 4 3 Installation 4 4 Overview of controls 5 5 Operating instructions 6 5 1 Switching on the sealer 6 5 2 Setting temperature...

Page 2: ...tted except by express consent Infringements are punishable and will lead to claims for damages We reserve all rights to exercise the provisions of commercial copyright law Warranty and liability We a...

Page 3: ...ll be accepted for use of the sealer for any other purpose The sealer may only be used for its intended purpose in accordance with the generally recognised rules of technology and the industrial healt...

Page 4: ...ackage will be difficult to peel open Paper fibres may be released and contaminate the sterile goods Released paper fibres may result in patient infection 3 Installation Set up the GS 43 sealer on a c...

Page 5: ...r guide to release the feed stop Move the feed stop to the required position and tighten the knurled nut With the feed stop fully forward the seam is about 5 mm away from the cut off edge of the mater...

Page 6: ...o flash The sealing temperature has been reached and the sealer is ready to seal 5 2 Setting temperature level 1 9 You can set the temperature level in ten steps Turn the switch A to the required posi...

Page 7: ...e temperature adjusts to the new setting and the red light starts to flash again If you raise the temperature the red light stays on continuously without flashing temperature too low Wait until the te...

Page 8: ...pulling it upwards as shown by the arrow Using a screwdriver 3 turn screw 4 clockwise to raise the temperature turn screw 4 anticlockwise to lower the temperature Refit the case cover 1 Danger of elec...

Page 9: ...ring breaks 6 Technical data SEALER GS 43 Dimensions w x d x h 570 x 280 x 240 mm approx Dimensions with paper guide 575 x 320 x 240 mm approx Weight 13 kg approx max sealing temperature 200 C Transpo...

Page 10: ...6 Pressure roller lower 4425723 Transport belt one 4416004 Toothed belts for pressure roller 4416016 Bearing bush 10 x 12 4415015 Ball bearing 4415000 From ____________________________________________...

Reviews: