Getinge GS 43 User Manual Download Page 3

 

Explanations 

Important instructions given in the technical documentation are indicated as 
follows: 

 Warning 

)

Useful information 

 

2 Safety 

regulations 

These instructions must be read and strictly complied with. 

 

2.1 Before 

use 

Users must familiarise themselves with the instructions in this manual before 
using the GS 43 sealer. 

 

2.2 Field 

of 

application 

The GS 43 sealer is to be used only for sealing sterilisation packages. No 
liability will be accepted for use of the sealer for any other purpose. 

The sealer may only be used for its intended purpose, in accordance with the 
generally recognised rules of technology and the industrial health and safety 
regulations. It must not be used if it has defects that might be dangerous to 
employees or third parties. 

 

2.3 

Danger of electric shock 

Before the case is opened, the sealer must be disconnected from the electric 
power supply. To open the case, unscrew the four unmarked internal hexagon 
screws with a 4mm key.  

Only an authorised technician or a specialist dealer may undertake servicing 
work on the sealer. 

 

 

 

GS-43-GB-002.doc  

3

Summary of Contents for GS 43

Page 1: ...er 4 2 5 Contamination of the sterilised goods Danger of patient infection 4 3 Installation 4 4 Overview of controls 5 5 Operating instructions 6 5 1 Switching on the sealer 6 5 2 Setting temperature...

Page 2: ...tted except by express consent Infringements are punishable and will lead to claims for damages We reserve all rights to exercise the provisions of commercial copyright law Warranty and liability We a...

Page 3: ...ll be accepted for use of the sealer for any other purpose The sealer may only be used for its intended purpose in accordance with the generally recognised rules of technology and the industrial healt...

Page 4: ...ackage will be difficult to peel open Paper fibres may be released and contaminate the sterile goods Released paper fibres may result in patient infection 3 Installation Set up the GS 43 sealer on a c...

Page 5: ...r guide to release the feed stop Move the feed stop to the required position and tighten the knurled nut With the feed stop fully forward the seam is about 5 mm away from the cut off edge of the mater...

Page 6: ...o flash The sealing temperature has been reached and the sealer is ready to seal 5 2 Setting temperature level 1 9 You can set the temperature level in ten steps Turn the switch A to the required posi...

Page 7: ...e temperature adjusts to the new setting and the red light starts to flash again If you raise the temperature the red light stays on continuously without flashing temperature too low Wait until the te...

Page 8: ...pulling it upwards as shown by the arrow Using a screwdriver 3 turn screw 4 clockwise to raise the temperature turn screw 4 anticlockwise to lower the temperature Refit the case cover 1 Danger of elec...

Page 9: ...ring breaks 6 Technical data SEALER GS 43 Dimensions w x d x h 570 x 280 x 240 mm approx Dimensions with paper guide 575 x 320 x 240 mm approx Weight 13 kg approx max sealing temperature 200 C Transpo...