As the condensate return unit operates without 
a float it is unaffected by waterhammer. 
Make sure that the booster steam line 
upstream of the solenoid valve is continuously 
drained by a GESTRA steam trap. 

Name plate 

The following items are indicated on the name 
plate: 

 

Manufacturer 

 

Type designation 

 

Min. service temperature 

 

Max. service temperature 

 

Max. service pressure  

 

Mark e.g. CE, UKCA (if required) 

 

Year of construction 

 

Serial number 

 

Type of vessel 

 

Weight 

 

Body of regulations 

 

Test pressure 

 

Test date 

 

Volume 

Application of European Directives  

Pressure Equipment Directive

 

The unit conforms to this directive (see 
"Manufacturer's Declaration" section) and can 
be used for the following media: 

 

Fluids of group 2 

ATEX 

The system must not be used in potentially 
explosive atmospheres. 

 

 

 

Attention! 

 

Unit can be damaged if stored or 
transported improperly. 

 

 

Close all openings with the 
sealing plugs or covers 
supplied with the unit or use 
similar sealing covers. 

 

Protect the unit against 
moisture and corrosive 
atmospheres. 

 

Please contact the 
manufacturer if the specified 
transport and/or storage 
requirements cannot be met. 

Storing the unit 

 

Please observe the following items when 
storing the unit: 

 

Do not store the unit for more than 12 
months. 

 

Use the supplied sealing plugs or other 
suitable seal caps in order to seal off all 
openings of the unit. 

 

Protect the sealing surfaces and contact 
areas against mechanical damage. 

 

Protect the unit and all components against 
hard shocks and impacts. 

 

Store the unit only in closed rooms that 
meet the following environmental 
conditions: 

 

Air humidity below 50 %, not 
condensing 

 

Indoor air: clean, salt-free and non-
corrosive  

 

Temperature 5

40 °C. 

 

 

Storing and transporting the unit 

Summary of Contents for KH

Page 1: ...Steam Powered Condensate Return Unit KH Original Installation Instructions 850801 00 ...

Page 2: ...rectives 7 Storing and transporting the unit 7 Storing the unit 7 Transporting the unit 8 Mounting and connecting the unit 8 Preparing installation 8 Connecting the unit 9 Commissioning 10 Operation 10 After Operation 10 Removing external dirt deposits 11 Maintaining the unit 11 Spare parts 11 Putting the unit out of operation 11 Removing harmful substances 11 Removing the unit 12 Re using unit af...

Page 3: ...it on Other applicable documents Further notes instructions and information on the components of the system can be found in the documentation of the respective manufacturer These documents form an integral part of these instructions Keep these documents together with these operating instructions Provide these documents if you sell the system or pass it on Formatting features in the document Certai...

Page 4: ...ions Selecting suitable lifting gear and understanding the rules for its safe use Working with dangerous contaminated hot or pressurized fluids The electrical personnel must also have knowledge and experience in electrical connection as well as of the current and mains voltage used If the admissible pressure and temperature ratings are exceeded the unit may be destroyed and hot or pressurised flui...

Page 5: ... must check the compatibility of the fluid with the housing material before commissioning The selection of a suitable housing material and suitable coating is the responsibility of the operator Qualification of personnel A qualified person must be acquainted with and experienced in the following the pertinent on site rules and regulations for preventing fire and explosions working on pressure unit...

Page 6: ...s the water level reaches the upper electrode tip max water level the solenoid valve in the vent line is closed by an amplifier and simultaneously the solenoid valve in the booster steam line introduced from above into the tank is opened The flowing steam pushes the condensate via the condensate main into the condensate tank The condensate level sinks and when the lower electrode tip emerges the s...

Page 7: ...ially explosive atmospheres Attention Unit can be damaged if stored or transported improperly Close all openings with the sealing plugs or covers supplied with the unit or use similar sealing covers Protect the unit against moisture and corrosive atmospheres Please contact the manufacturer if the specified transport and or storage requirements cannot be met Storing the unit Please observe the foll...

Page 8: ...to seal off the connections For short distances only a few metres you can transport the unit unpacked When transporting the unit over larger distances use the original packaging If you do not have the original packaging use a box that protects the unit adequately against corrosion and physical damage For a short period of time the unit may be transported even if the temperature is below 0 C provid...

Page 9: ...in making pipe connections for the respective type of end connection Connect the system only as described in this operating manual CAUTION Environmental damage caused by leaking medium in case of damaged seal Make sure that the sealing surfaces are undamaged Clean the sealing surfaces before installing a new seal Replace each seal after removal Attention The unit can be damaged if connections are ...

Page 10: ...tions if required The condensate return unit operates automatically Do not work on the unit while it is operating DANGER If the unit is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the unit Only qualified personnel are allowed to perform work on contaminated equipment Always wear the protective clothing prescribed for contaminated are...

Page 11: ...areas there is a risk of severe injuries or death caused by harmful substances in or on the unit Only qualified personnel are allowed to perform work on contaminated unit Always wear the protective clothing prescribed for contaminated areas when working on the unit Make sure that the unit is completely decontaminated before carrying out any service work Follow the pertinent instructions for handli...

Page 12: ...ta sheet of the fluid in question DANGER Risk of bruises if the unit or component parts fall down Use suitable lifting gear when moving or lifting the unit and or component parts Make sure that the unit cannot topple over Make sure that nobody is standing below the lifted unit Store the unit as described in section Storing the unit Re using unit after storage Observe the following instructions if ...

Page 13: ...the return delivery with your contractual partner before returning the unit Pressure temperature ratings You can find the values for your unit on the name plate Weights You can find the values for your unit on the name plate You can find details on the conformity of the unit in our Declaration of Conformity or Manufacturer s Declaration You can download the latest Declaration of Conformity or Manu...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...the world www gestra com GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon 49 421 3503 0 Telefax 49 421 3503 393 E Mail info de gestra com Web www gestra de 850801 00 11 2021_mw GESTRAAG Bremen PrintedinGermany ...

Reviews: