background image

8

4.   Remove the 2 carbon brush screws and take out the carbon brushes. Be 

careful not to lose screws.

5.  Install the new Carbon Brushes and secure with screws (Fig. 4).

6.    Gently push down the On/Off motor switch to free the motor cord from 

the motor cap. Be careful not to damage the On/Off motor switch. Then 
plug the motor cord back into the motor (Fig. 5)

7.   Dust Removal - From time to time, it will be necessary to clean excessive 

dust that accumulates in the motor cover. To remove this dust, remove 
the motor cap (see instructions for replacing carbon brushes to remove 
motor cap). If compressed air is available, use it inside the cover and the 
motor armature air cooling vent. If air is not available, remove excessive 
dust with a dry brush. If necessary, use a cloth moistened with detergent 
to clean the cover, and blow into the air cooling vents to clean around the 
armature. 

DO NOT USE

 

any volatile liquid as a cleaner (i.e. paint thinner 

or alcohol). 

     Periodically cleaning the inner threads on handpiece collets will ensure 

their easy collet removal when changing sizes. Twist a clean rolled-up 
piece of tissue paper in and out of the threaded area.

Fig. 4

Fig. 5

8.   Align the On/Off motor switch with the square hole of the motor cap, and 

gently insert motor cap (Fig. 6 & 7). Then insert the motor cap screw.

9.   While the power is off, plug handpiece into controller. Please speed up 

gradually from minimum RPM and make sure nothing is abnormal with 
behavior.

10.  

 

Lubrication

 - 

Lubrication of your Gesswein Power Hand 3 Rotary 

Handpiece 

IS NOT NECESSARY, and you should NOT let oil or other 

fluids enter the Head Assembly (see Precautions).

9

Fig. 6

Fig. 7

Summary of Contents for POWER HAND 3

Page 1: ...Instruction Manual for 35 000RPM Motor Assembly Model PH3 35X 510 3351 ...

Page 2: ...six motors and eight head assemblies with maximum operating speeds ranging from 8 000 to 55 000rpm The maximum RPM speed is indicated on each motor case housing To connect Power Hand 3 handpieces to Power Hand 2X controllers use the PH3 Adaptor 5 to 3 prong reducer plug 510 3304 3 Accessories Included Accessories A Two Carbon Brushes reorder 510 0169 Optional Accessories A Handpiece Extension Cord...

Page 3: ...r Hand 3 Controller to an electrical supply and the handpiece to the A motor or B motor output socket Put the Controller Main Switch to the ON position which lights up the LED lights of controller Then select the A motor or B motor button depending on which socket the handpiece is plugged in to Check to make sure the desired rotational direction is selected on the Fwd Rev button Then press the STA...

Page 4: ...ect the power cord on the handpiece to sharp bending or rough treatment Such treatment could break the cord wires or damage the male connecting pins and female cord connectors H Be careful not to point the handpiece at any part of the body while it is running particularly during startups I Be careful when using Wire Burnishing Tools DO NOT USE THESE TOOLS AT SPEEDS FASTER THAN 14 000 15 000RPM Eac...

Page 5: ...t with a dry brush If necessary use a cloth moistened with detergent to clean the cover and blow into the air cooling vents to clean around the armature DO NOT USE any volatile liquid as a cleaner i e paint thinner or alcohol Periodically cleaning the inner threads on handpiece collets will ensure their easy collet removal when changing sizes Twist a clean rolled up piece of tissue paper in and ou...

Page 6: ...2320 Armature Completed KA10 115 510 2321 Armature KF 204A 896 0096 Dust Proof Collar KF 201A 896 0097 Dust Proof Collar 830ZZ 510 3076 Ball Bearing S 8 896 0098 O Type Rubber Ring HE5E 205 896 0099 Metal Rear Lid ON08 201 896 0100 O Type Rubber Ring UM10 202 896 0336 Brush Side Lid PKE60 101A 510 0169 Carbon Brush set of 2 YSP21 114 896 0337 Pan Head Screw KE 548C 896 0102 Terminal Plate KE 548D ...

Page 7: ... reciprocating profilers One side to side profiler Belt Sander Power Hand 3 controllers and handpieces combine to create the most versatile finishing system in the industry offering rotary profiling and belt sanding action 201 Hancock Ave Bridgeport CT 06605 USA orders 800 243 4466 203 366 5400 fax 203 366 3953 email info gesswein com www gesswein com ...

Reviews: