background image

 

R

R

R

-

-

-

G

G

G

-

-

-

B

B

B

 

 

Channel 

Function 

Time and Value 

DMX 

HEX 

5) Red-
 coarse 

Color mixing system – Red  

0 - 100% 

0..255 

00..FF 

0..100 

6) Red-fine 

Color mixing system – Red-Low 

 

0..255 

00..FF 

0..100 

7) Green-
 coarse 

Color mixing system – Green  

0 - 100% 

0..255 

00..FF 

0..100 

8) Green-
 fine 

Color mixing system – Green-Low 

 

0..255 

00..FF 

0..100 

9) Blue-
 coarse 

Color mixing system – Blue  

0 - 100% 

0..255 

00..FF 

0..100 

10) Blue-fine 

Color mixing system – Blue-Low 

 

0..255 

00..FF 

0..100 

11) Shutter 

Shutter closed 

 

0..15 

00..0F 

0..5,5 

 

Random Pulse effect 

slow - fast 

16..47 

10..2F  6..18,5 

 

Up-dimming then Shutter closing 
(random patterns)  

slow - fast 

48..79 

30..4F  19..31,5

 

Shutter open then down-dimming 
(random patterns) 

slow - fast 

80..111 

50..6F 

32..43 

 

Up-dimming then down-dimming 
(random patterns) 

slow - fast 

112..143  70..8F 

44..56 

 

Strobe effect pause  

5s to 1s 

144..199  A0..C7

57..77 

 

Strobe effect, slow - fast 

1 Hz .. 10 Hz 

200..239  C8..EF

78..94 

 

Shutter open 

 

240...249  F0..F9  95..97,5

 

RESET 

Min. 3 Sec. 

250 

FA 

98 

 

Shutter open  

 

251..255  FB..FF 99..100

12) Dimmer-
 coarse 

Dimmer  

0% - 100% 

0..255 

0..FF 

0..100 

13) Dimmer-
 fine 

Dimmer - Low 

 

0..255 

0..FF 

0..100 

 

1)

 The predefined colors can be used as start-colors for the Rainbow effect. Please select first a 

desired start-color before you activate the rainbow effect. All 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

X

X

L

L

s

s

 will afterwards start 

from that color and will execute the rainbow effect synchronously. Different 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

X

X

L

L

s

s

 can 

certainly have different start-colors but will still execute the rainbow effect synchronously. If you 
choose a color different from the once marked with 

1)

 in the tables above the rainbow start-color will be 

red.  

2)

 Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with 

the current color.  
 

3)

 The Rainbow-effect will run synchronously only if it will be started going out from one of the 

predefined colors (see also 

1)

 before).  

 

Additional Display Indication  

As a default you'll find the following additional information in the first row of the LCD display:  

XX/X/XX 
 

06 = 600Hz / 12 = 1200Hz 

 

N = Normal Mode / C = Compressed Mode / H = High Res. Mode 

 

N = Tilt normal / I = Tilt inverted  

 

N = Pan normal  / I = Pan inverted 

 

GLP 

Š

 German Light Products GmbH 

(Manual Version 1. / from Software Version 1.09/0.3)

 

16

 

Summary of Contents for Impression XL

Page 1: ...Usermanual from Software Version 1 09 0 3 Manual Version 1 00 e mail service glp de Internet http www glp de ...

Page 2: ...For your notes ...

Page 3: ...irst 8 2 1 3 Mounting in sidewise Position 8 2 2 Secure the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 The Menu Field 10 4 DMX Channel Sheet 12 5 Maintaining and Cleaning the IMPRESSION 17 5 IMPRESSION 5 1 Safety regulations 17 5 2 Circumference and Interval rule of thumb 17 6 Technical Specifications 18 7 Index 19 GLP German Light Products GmbH Manual Version 1 from Software Ve...

Page 4: ...various connectors and Camlock mounting system Æ Safety eyes 5 DMX Output 5 Pin 6 DMX Output 3 Pin 7 Micro fuse 6 3x32mm T15A 8 Power On Off 9 2x Safety eyes 10 Powercon Mains supply 11 Empty 12 DMX Input 3 Pin 13 DMX Input 5 in Only connect one cable to the DMX Out Input at a time GLP German Light Products GmbH Manual Version 1 from Software Version 1 09 0 3 4 ...

Page 5: ...l 6 The system doesn t contain any maintainable parts Don t open it 7 It is necessary to wait at least 15 minutes after disconnecting the AC before changing the optical carrier Pay attention to possibly hot parts of the system Danger of BURNING 8 Never look directly into the beam of light or one of the LEDs Never use optical apertures with a distance less than 0 5 m to observe the beam of light LE...

Page 6: ... 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X XL L standing on the floor sideways or hanging different accessories kits are available Through this a safe and firm installation is assured You ll find special connectors on the bottom side of the system which are put to use here In addition the front side of...

Page 7: ...ide of the system It is fixed with fasteners called Camlock quick release connectors Turn the two fasteners both 90 to lock them Do the opposite to release them again On both sides you ll find eyelets to pull though a fixing strap This allows an additional bracing of the system during the upright operation GLP German Light Products GmbH Manual Version 1 from Software Version 1 09 0 3 7 ...

Page 8: ...ed by two Camlock quick release connectors Two half couplers clamps are now used to mount the system to a standard truss bar This technique is necessary to cope with the torque which accrues in this mounting position In addition it allows a concentrically position between two truss belts Never use the Mounting in hanging Position technique described above to fasten the system in the sidewise posit...

Page 9: ...es the weight of the fixture Never use the carrying handles for this purpose 2 3 Connections 2 3 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact type plug Powercon Connected load 1200 VA W 14 AT micro fuse 5x20mm Please see printing on the case for the right electronic supply Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 2 3 2 DMX USI...

Page 10: ... Tilt movements Æ see also item below Pan Tilt Movements Manual control for Pan Tilt movement Special Activate the White or Full Power Mode see also DMX table White Temperature Abgleich der Farbtemperatur der Farbe WEIß Dimmer Manual control for Dimmer Shutter Manual control for Shutter Blue Manual control for blue Green Manual control for green Red Manual control for red Color Wheel Manual contro...

Page 11: ...mperature PAN TILT Motor Power Switches power for Pan Tilt ON or OFF disconnected from power PAN TILT Silent Mode Reduces maximum speed for Pan Tilt DMX Hold Defines whether the last DMX signal is stored or the lamp is switched OFF in case of signal interruption Position Feedback Automatically position feedback correction for Pan Tilt movement White Adjust Adjustments for a uniform white color whi...

Page 12: ...Blackout ON OFF Display OFF Select DMX Mode Please select the desired DMX Mode Compressed Only 10 DMX channels are being used if this Mode is activated Normal 14 DMX channels are being used if this Mode is activated High Resolution 13 DMX channels are being used if this Mode is activated Dimmer operates at 16 bit White Mode ON OFF Adjustments for white balance are activated Reverse Pan ON OFF Inve...

Page 13: ... 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19 31 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Str...

Page 14: ...Mode is used with RGB can be selected in the Normal DMX Mode during operation with the Special DMX channel If the Special channel is set to a value between DMX 0 15 the White Mode is not used and the RGB goes for the maximum light output If the Special channel is set to a value between DMX 16 31 the white balance is used for the RGB output Since there is no Special DMX channel in the Compress DMX ...

Page 15: ...ast 224 255 E FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random p...

Page 16: ...13 Dimmer fine Dimmer Low 0 255 0 FF 0 100 1 The predefined colors can be used as start colors for the Rainbow effect Please select first a desired start color before you activate the rainbow effect All I Im mp pr re es ss si io on n X XL Ls s will afterwards start from that color and will execute the rainbow effect synchronously Different I Im mp pr re es ss si io on n X XL Ls s can certainly hav...

Page 17: ... cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used 5 1 Safety regulations Pull out the main plug Wait min 15 minutes after the last operation to cool down the fixture 5 2 Circumference and Interval rule of thumb The contamination of the fixture depends on the environment details Hence no general guidelines can be given The i...

Page 18: ...efficient Collimator cluster Exchangeable optical carrier with 10 light distribution angle 25 optional Scattering light aperture Shutter Dimmer 8 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 DMX Addressing starts at the DMX channel 001 Pan Tilt 8 16 ...

Page 19: ...Field 10 Micro fuse 9 Mode key 10 Mounting 5 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting on the Floor 7 N Normal Mode 12 O Optical parts 17 P Pan Movement 18 Power Supply 9 S Safety distance 5 Safety Instructions 5 Secure the Device 9 Software Version 1 T Technical Specifications 18 Tilt Movement 18 U Up Down keys 10 V VBG 70 6 W Warranty claims 5 Weights and Measures 1...

Page 20: ...R R R G G G B B B GLP German Light Products GmbH Manual Version 1 from Software Version 1 09 0 3 20 ...

Reviews: