 fixture from GLP is fitted with a number of plano-

convex lenses in a highly efficient collimator cluster. This type of lens can act as 

a strong magnifying glass. 

If the rays from a strong light source (such as the sun or another lighting fixture) 

are  directed  towards  the  front  of  any  of  these  fixtures,  then  internal  damage 

may  occur.  In  a  worst  case  scenario  with  a  high  power  light  source  this  can 

happen  very  quickly,  damaging  the  fixture  internally,  potentially  melting 

components or causing an internal fire within seconds.  

In  order  to  avoid  these  possible  problems  please  adhere  to  the  following 

requirements: 

  Do not expose the front of a fixture to direct sunlight or any other strong 

light sources. 

  For outdoor applications during daylight make sure that the front face of 

any  fixture  is  either  shielded  or  points  away  from  the  sun,  even  when 

fixtures are not in use. 

  Do not modify the front glass or lenses of any fixture.  

These  requirements  have  to  be  followed  regardless  of  whether  a  fixture  is 

powered  on  or  off  as  the  magnifying  effect  is  an  optical  effect  and  therefore 

independent from the (electrical) state of the fixture. 

 

Especially when working with high powered 

b

b

e

e

a

a

m

m

-

-

l

l

i

i

g

g

h

h

t

t

s

s

; extreme caution and 

observance of these safety instructions is mandatory. 

 

 

 

All manuals and user guides at all-guides.com

Summary of Contents for Impression X4 Bar 20

Page 1: ...from software version v0 26 Instruction Manual X4 Bar 20 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ... or sideways position 7 2 3 Securing the Fixture 7 2 4 Connections 7 2 4 1 Power Supply 7 2 4 2 DMX 8 3 The Menu Field 8 4 DMX Chanel Selection DMX Protocol 9 4 1 Normal Mode norm 34 DMX channels 9 4 2 Compressed Mode comp 20 DMX Channels 11 4 3 Single Pixel Mode spix 88 DMX Channels 13 5 Maintaining and Cleaning 16 5 1 Safety regulations 16 5 2 Maintenance and Interval rule of thumb 16 6 Technica...

Page 3: ...ely and passively cooled 2 LCD Display Menu data entry 3 Base with rubber feet and Camlock mounting system A Base side left B Base side right 4 DMX Input 5 pin 5 Mains Input blue powerCON 6 Micro fuse 5x20mm T5A 7 Mains Output white powerCON 8 DMX Output 5 pin 1 2 3 4 5 6 7 8 A B All manuals and user guides at all guides com ...

Page 4: ... minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture Danger of BURNING 6 Never look directly into the beam of light or into one of the LEDs Never use optical apertures to observe the beam of light LED Class 2M You ll risk serious injury of your eyes and in particular of your retina Attention LED Class 2M can cause injuries of y...

Page 5: ...elting components or causing an internal fire within seconds In order to avoid these possible problems please adhere to the following requirements Do not expose the front of a fixture to direct sunlight or any other strong light sources For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun even when fixtures are not in ...

Page 6: ...standing on the floor Keep a safety distance of min 0 5 m towards any easily inflammable materials decoration etc Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X4 4 B Ba ar r 2 20 0 standing on the floor sideways or hanging different acce...

Page 7: ...e to release them again 2 3 Securing the Fixture Regardless of the mounting method of the I IM MP PR RE ES SS SI IO ON N X X4 4 B Ba ar r 2 20 0 you ll have to use a stipulated safety wire Attach the safety wire through the bracket on the base of the fixture and connect it to the primary support structure Pay attention to a safe and proper fastening The safety cable must comply with BGI 810 3 EN 6...

Page 8: ...e DMX Addressing starts at the DMX Address 001 3 The Menu Field To lock or unlock the keys of the menu field press Mode Enter Up simultaneously You ll find the control board on the side part of the arm It allows you to make all necessary adjustments of the I IM MP PR RE ES SS SI IO ON N X X4 4 B Ba ar r With the Mode key you get into the main menu Afterwards you can Navigate through the menu with ...

Page 9: ... 1 56 63 Color 08 Blue 1 64 71 Color 09 Lavender 1 72 79 Color 10 Malve 1 80 87 Color 11 Magenta 1 88 95 Color 12 Pink 1 96 103 White CTO 3200K 104 111 White 5600K 112 119 White CTB 7200K 120 127 Rainbow Effect Stop 2 128 Rainbow Effect 3 slow fast 129 223 Random colors slow fast 224 255 6 Set 1 Red Color mixing system Red 0 100 0 255 7 Set 1 Green Color mixing system Green 0 100 0 255 8 Set 1 Blu...

Page 10: ...m White 0 100 0 255 19 Set 2 Intensity 4 Intensity 0 100 0 255 20 Set 3 Color 4 Values see Channel 5 21 Set 3 Red 4 Color mixing system Red 0 100 0 255 22 Set 3 Green 4 Color mixing system Green 0 100 0 255 23 Set 3 Blue 4 Color mixing system Blue 0 100 0 255 24 Set 3 White 4 Color mixing system White 0 100 0 255 25 Set 3 Intensity 4 Intensity 0 100 0 255 26 Crossfade 0 2 seconds transistion time ...

Page 11: ...96 103 White CTO 3200K 104 111 White 5600K 112 119 White CTB 7200K 120 127 Rainbow Effect Stop 2 128 Rainbow Effect 3 slow fast 129 223 Random colors slow fast 224 255 6 Set 1 Red Color mixing system Red 0 100 0 255 7 Set 1 Green Color mixing system Green 0 100 0 255 8 Set 1 Blue Color mixing system Blue 0 100 0 255 9 Set 1 White Color mixing system White 0 100 0 255 10 Shutter Shutter closed 0 15...

Page 12: ... Applicable 8 255 for ALL colors 13 Special RESET 1 sec 250 255 14 Crossfade 0 2 seconds transistion time 0 255 15 Set 1 Pattern 0 255 Movement 16 Zoom Wide flood narrow spot 50 7 0 255 17 Set 1 Pattern 0 255 Select 18 Pixel Select 0 255 1 8 19 Pixel Select 0 255 9 16 20 Pixel Select 0 255 17 20 All manuals and user guides at all guides com ...

Page 13: ...ing system Red 0 100 0 255 10 Set 1 Green Color mixing system Green 0 100 0 255 11 Set 1 Blue Color mixing system Blue 0 100 0 255 12 Set 1 White Color mixing system White 0 100 0 255 13 Set 2 Red Color mixing system Red 0 100 0 255 14 Set 2 Green Color mixing system Green 0 100 0 255 15 Set 2 Blue Color mixing system Blue 0 100 0 255 16 Set 2 White Color mixing system White 0 100 0 255 17 Set 3 R...

Page 14: ...0 0 255 45 Set 10 Red Color mixing system Red 0 100 0 255 46 Set 10 Green Color mixing system Green 0 100 0 255 47 Set 10 Blue Color mixing system Blue 0 100 0 255 48 Set 10 White Color mixing system White 0 100 0 255 49 Set 11 Red Color mixing system Red 0 100 0 255 50 Set 11 Green Color mixing system Green 0 100 0 255 51 Set 11 Blue Color mixing system Blue 0 100 0 255 52 Set 11 White Color mixi...

Page 15: ...0 100 0 255 82 Set 19 Green Color mixing system Green 0 100 0 255 83 Set 19 Blue Color mixing system Blue 0 100 0 255 84 Set 19 White Color mixing system White 0 100 0 255 85 Set 20 Red Color mixing system Red 0 100 0 255 86 Set 20 Green Color mixing system Green 0 100 0 255 87 Set 20 Blue Color mixing system Blue 0 100 0 255 88 Set 20 White Color mixing system White 0 100 0 255 The Pixel are numb...

Page 16: ...ar cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used 5 1 Safety regulations Pull out the mains power plug Wait min 15 minutes after disconnecting power to allow the fixture to cool ...

Page 17: ...resentable color space Optical System Full RGBW High efficient Collimator cluster Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Pulse Effects Continuous Dimmer 0 100 Zoom 7 to 50 degree continuous zoom Optical Patterns Several pre defined beam patterns with direct access and manipulation DMX Control Standard USITT DMX 512 5 pin XLR Pin 3 Pin 2 Gro...

Page 18: ...GLP German Light Products GmbH Impression X4 Bar 20 from software version v0 26 18 7 Dimensions All manuals and user guides at all guides com ...

Page 19: ...GLP German Light Products GmbH Impression X4 Bar 20 from software version v0 26 19 All manuals and user guides at all guides com ...

Reviews: