2.2.1 Operating on the Floor (Upright)
The
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
B
B
a
a
r
r
2
2
0
0
is fitted with 4x solid rubber feet which allows a
stable standing of the fixture. An additional securing is usually not required.
Please pay attention to an even and gripping surface.
2.2.2 Mounting in hanging or sideways position
To operate the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
B
B
a
a
r
r
2
2
0
0
in a hanging position please use the two
(2) dedicated brackets supplied with your fixture. They are fixed to the base of the
fixture with fasteners called Camlock quick-release connectors. Insert the four
fasteners of each and turn each 90° to lock them. Do the opposite to release them
again.
2.3 Securing the Fixture
Regardless of the mounting method of the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
B
B
a
a
r
r
2
2
0
0
you'll have to
use a stipulated safety wire. Attach the safety wire through the bracket on the
base of the fixture and connect it to the primary support structure. Pay attention to
a safe and proper fastening. The safety cable must comply with BGI 810-3 (EN
60598-2-17 Section 17.6.6) and be capable of bearing a static suspended load
that is ten times the weight of the fixture and all installed accessories.
2.4 Connections
2.4.1 Power Supply
~100-240 Volt AC, 50-60 Hz, powerCON AC connector
Connected load 450 VA (W) <=> T5A (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
4 x Camlock for bracket #1
4 x Camlock for bracket #2
All manuals and user guides at all-guides.com