The Web Interface
15
3
[ID]
Enter the ID number for the controller. This ID is used by GV-ASManager to differentiate
among multiple units of controllers. ID number can only be between 1 and 1000.
[Door/Gate A]
Select the function type and authentication mode for the use of the door/gate.
Function:
Define the function of the controller connected to the door/gate which is used
for door, parking lost or elevator access control.
Authentication Mode:
Select the authentication mode for the door/gate.
Local Unlock Mode:
Remains open. The held-open state cannot be cleared
through GV-ASManager.
Local Lock Mode:
Remains locked. The locked state cannot be cleared through
GV-ASManager.
Fixed Card Mode:
Grants access after the card is presented or a passcode is
entered, and ignores the authentication schedule of GV-ASManager.
Fixed Card Mode + PIN Mode:
Grants access after the card is presented and the
card’s PIN code entered too. Ignores the authentication schedule of GV-ASManager.
Fixed Card/Common Mode:
Grants access after the card is presented or after the
door/gate’s password is entered. Ignores the authentication schedule of GV-
ASManager.
Authentication Schedule Mode:
Follows the authentication schedule set on GV-
ASManager.
Local Lock Down:
Locks down the door and denies access when the card is
presented. Ignores the Lock Time setting and APB setting.
Note:
To grant access to a card in
Local Lock Down
mode, click the
Access Monitor
button on GV-ASManager, right-click on the card to select
New/Edit Card
and select
Disable
Lock Card / Disable APB / Allow Access during Lockdown Mode
.