23
ASTON CONSOLE SERIES INSTALLATION MANUAL
Wiring Schematics, cont.
CCM - with ECM, Electric Heat and Electronic Stat
208-230-265/60/1
24V
Transformer
EH
CC
Legend
LP
HP
Unit
Power Supply
208-230/60/1 or
265-277/60/1
G
Handi - Box
Ground
Lug
Cycled
Continuous
CC
T2
T1
Compressor
C
R
S
Tan (33)
Red
Blk
Blue
L1
L2
High
Low
Auto
Fan
6
1
3
2
4
5
COMPRESSOR
CONTROL MODULE
TEST
PIN
HP
HP
CC
CG
LO
R
C
LP
LP
Y
HP
HP
CC
CG
LO
R
C
LP
LP
Y
Blue
230V
265V
Red
208V
Black
Yellow
Black/White
Black/White (1)
Red (2)
Black (6)
Black (7)
Blue (8)
Blue (9)
Ther
mistor
Electronic THERMOSTAT
T1
T3
B Cool
A Heat
T2
T4
T6
T5
SHUT
DOWN
24 V
AC
IN
PUT
T6
T4
T5
T2
T1
T3
Overide
Shut down
J1
Red
Violet (5)
Yellow (13)
Yellow (10)
White (20)
Orange (14)
Orange (21)
Orange
Black (12)
White (18)
Red (11)
Red (19)
Red (17)
24 V Accessory
24VAC
Shutdown
Red (15)
Red (16)
NOTE 1
T
ST
Black
Black
Red (11)
Black (12)
Red
(17)
Red (19)
Black (25)
Black (31)
Red (32)
Brown (26)
Black (27)
RB
4
2
5
Red
EH
T2
T1
L2
White
White
L1
EHS
Normal
RV
DT
ON
OFF
Damper Switch
Damper
Motor
D
Fan Mode Sw
4
5
2
E1
E1
AQ
Blk/Wht (24)
Blk/Wht (23)
Black (22)
White (18)
Blue (T6)
NOTE 2
3
1
RB
3
1
Black (37)
Blue (38)
Blue/Wht (36)
Blue/Wht (35)
White (34)
Blue (T6)
FS
Yellow (44)
Yellow (44)
Brown (43)
Yellow (13)
Page 1
Blue
Tan (41)
Blue (40)
Blue (40)
Brown (3)
Tan (41)
Brown (26)
Green (00)
Red (39)
Gray (42)
NOTE 3
NOTE 4
Violet (4)
Violet (4)
Violet (5)
Factory low voltage wiring
Temperature Switch
Factory line voltage wiring
Quick connect terminal
Wire nut
Notes:
1. Switch Red and Blue wires for 208 volt
operation
Field low voltage wiring
Field line voltage wiring
CC - Compressor Contactor
HP - High Pressure Switch
LP - Low Pressure Switch
RV - Reversing Valve Coil
ST - Entering Air Temperature Sensor
RB - Blower Relay
2. Terminal C of 24 V PB is used as “L”
output for Brown wire 3 for Lockout.
Legend
DT - Damper Terminal Block
PB - Power Block
Field wire lug
Earth Ground
Relay Contacts -
N.O., N.C.
Polarized connector
1
3
2
P
Switch - High Pressure
Switch - Low Pressure
Relay coil
Capacitor
Thermistor
HP
LP
T
L1
3. Optional field installed freeze sensing device.
FS - Freeze Sensing Device
4. Optional field installed aquastat.
AQ - Aquastat
EH - Electric Heat Contactor
E1 - Electric Heat Relay
PB
1
2
3
Mode Switch
Fan Switch
EHS – Electric Heat Switch
Note 5
ECM
Motor
Green/Yellow
ECM
Motor
Module
Blue
Yellow
White
5. Factory wired. Refer to blower table settings.
Red
Black
High
Low
NC*09
Yellow
White
NC*12
Blue
Yellow
NC*15
Yellow
White
NC*18
Blue
Yellow
Blower Se
ƫ
ngs
CHART 1