4
ASTON COMPACT INSTALLATION MANUAL
Model Nomenclature
1-2
GB
4-6
036
7
T
8
L
9
0
10
0
11
0
12
C
13
A
14
N
15
A
16
N
17
1
21-22
SS
18
A
19
1
20
0
23
*
3
V
Model Type
GB = Aston Compact
Cabinet Configuration
V = Vertical
H = Horizontal
Unit Capacity
Single
Speed
009, 012, 015, 018, 024, 030,
036, 042, 048, 060, 070
Dual
Capacity
026, 038, 049, 064, 072
Discharge Configuration
T = Top (vertical)
E = End (horizontal)
S = Side (horizontal)
Return Air Configuration
L = Left
R = Right
Voltage
0 = 208-230/60/1
2 = 265-277/60/1
(009-038)
3 = 208-230/60/3
(024-072)
4 = 460/60/3
(024-072)
5 = 575/60/3 (PSC only 042, 048, 060, 070)
Refrigeration Option
0 = None
2 = HWG only w/o pump (Vertical 018-070)
G = Hot Gas Bypass (015-072)
R = Hot Gas Reheat (015-072)
B = Hot Gass Bypass w/ Hot Gas Reheat (015-072)
Blower Option
0 = PSC Blower (single speed)
1 = Variable Speed ECM Blower (015-072)
2 = High Static Variable Speed ECM Blower
(036, 038, 042, 048, 049)
3 = High Static PSC Blower (024, 030, 036, 042, 048)
4 = 5-Speed ECM Blower (015-072)
Water Coil Option
C = Copper
D = Insulated
Copper
N = Cupronickel
P = Insulated
Cupronickel
NOTES:
Phase guard only available on 208-230/60/3, 460/60/3, and 575/60/3
Model Type
GB = Aston Compact
Cabinet Configuration
V = Vertical
H = Horizontal
Unit Capacity
Single
Speed
009, 012, 015, 018, 024, 030,
036, 042, 048, 060, 070
Dual
Capacity
026, 038, 049, 064, 072
Discharge Configuration
T = Top (vertical)
E = End (horizontal)
S = Side (horizontal)
Return Air Configuration
L = Left
R = Right
Voltage
0 = 208-230/60/1
2 = 265-277/60/1
(009-038)
3 = 208-230/60/3
(024-072)
4 = 460/60/3
(024-072)
5 = 575/60/3 (PSC only 042, 048, 060, 070)
Refrigeration Option
0 = None
2 = HWG only w/o pump (Vertical 018-070)
G = Hot Gas Bypass (015-072)
R = Hot Gas Reheat (015-072)
B = Hot Gass Bypass w/ Hot Gas Reheat (015-072)
Blower Option
0 = PSC Blower (single speed)
1 = Variable Speed ECM Blower (015-072)
2 = High Static Variable Speed ECM Blower
(036, 038, 042, 048, 049)
3 = High Static PSC Blower (024, 030, 036, 042, 048)
4 = 5-Speed ECM Blower (015-072)
Water Coil Option
C = Copper
D = Insulated
Copper
N = Cupronickel
P = Insulated
Cupronickel
NOTES:
Phase guard only available on 208-230/60/3, 460/60/3, and 575/60/3
Vintage
* = Factory Use Only
Non-Standard Option Details
SS = Standard Option
Drain Pan Option
0 = Composite, No Secondary Connection
1 = Composite, Secondary Connection
2 = Stainless Steel, No Secondary Connection
3 = Stainless Steel, Secondary Connection
Air Coil Option
1 =
Standard
2 =
FormiShield™
Filter Option
A = MERV
4
B = MERV
13
Cabinet Option
0 = Unpainted Cabinet, Filter Rail
1 = Painted Cabinet, Filter Rail
2 = Unpainted Cabinet, 4-sided Filter Rack
3 = Painted Cabinet, 4-sided Filter Rack
Electrical Option
N = None
A = GeoStart
®
Only
E = GeoStart and Disconnect
P = Phase Guard, No Disconnect
B = Phase Guard, Disconnect
D = No Phase Guard, Disconnect
Controls Option
A =
Aurora
TM
Base Control (ABC)
4 = FX10 std. no communication
5 = FX10 w/ Open N2 Com Card
6 = FX10 w/ LonWorks Com Card
7 = FX10 w/ BacNet Com Card
Water Control Option
N = None
R = Water Flow Regulator
V = 2-Way Valve
B = 2-Way Valve w/ Water Flow Regulator
Sound Kit Option
A = None
B = Sound Kit
Rev.:
25 February 2013D
Vintage
* = Factory Use Only
Non-Standard Option Details
SS = Standard Option
Drain Pan Option
0 = Composite, No Secondary Connection
1 = Composite, Secondary Connection
2 = Stainless Steel, No Secondary Connection
3 = Stainless Steel, Secondary Connection
Air Coil Option
1 =
Standard
2 =
FormiShield™
Filter Option
A = MERV
4
B = MERV
13
Cabinet Option
0 = Unpainted Cabinet, Filter Rail
1 = Painted Cabinet, Filter Rail
2 = Unpainted Cabinet, 4-sided Filter Rack
3 = Painted Cabinet, 4-sided Filter Rack
Electrical Option
N = None
A = GeoStart
®
Only
E = GeoStart and Disconnect
P = Phase Guard, No Disconnect
B = Phase Guard, Disconnect
D = No Phase Guard, Disconnect
Controls Option
A =
Aurora
TM
Base Control (ABC)
4 = FX10 std. no communication
5 = FX10 w/ Open N2 Com Card
6 = FX10 w/ LonWorks Com Card
7 = FX10 w/ BacNet Com Card
Water Control Option
N = None
R = Water Flow Regulator
V = 2-Way Valve
B = 2-Way Valve w/ Water Flow Regulator
Sound Kit Option
A = None
B = Sound Kit
Rev.:
25 February 2013D
Summary of Contents for Aston Compact Series
Page 2: ......