11. MAINTENANCE
11.1. Lubrication and Cleaning
The
Geosense®
MEMS Digital Inclinometer is a low maintenance device. With
careful use, routine inspections and a small amount of maintenance, it will provide
reliable data over a long period.
Upon completion of a monitoring exercise it is strongly recommended that the probe
and cable be wiped down to remove moisture and detritus. The connector caps
should be fitted whenever the connector is separated. Do not store a wet cloth with
the probe in the hard case. Connectors should always be dry and free from dirt
before being stored for any periods, as trapped moisture may cause corrosion.
The probe wheels include sealed bearings so cannot be lubricated. However, the
wheel carriage spindles should be occasionally lubricated with a light machine oil, to
maintain free movement and reduce wear.
The cable connector includes a double ‘O’ ring sealing system. The ‘O’ rings should
be wiped clean and lubricated with a small amount of Silicon Grease to maintain
ease of connection.
DO NOT lubricate the electrical contact pins or use oil on the
connector parts.
DO NOT clean the connector parts with chemical
compounds. Use water only.
DO NOT use WD-40 or any other lubricant spray that contains
solvents.
Batteries in the Reel and the CAT S42 should be charged regularly to prevent
deterioration and maintain their capacity. Only approved chargers should be used.
General Inspections should include the following...
Do not use electrical contact cleaners, especially sprays. Any solvents in these
products will attack the neoprene inside the connectors. When used on neoprene, it
swells and reduces the effectiveness of the O-ring seals.