V1.1
MEMS Digital Portable Horizontal Inclinometer
09/02/2022
28
16)
Remove the cover from the inclinometer access tube if there is one. (A
secure cover is strongly recommended to stop any foreign objects or animals
entering the pipe work. Horizontal installations if not sealed can house rodents
which can deposit nesting material that will block the access casing)
Prior to any horizontal survey, the pull rope must have
been installed within the inclinometer casing.
NEVER remove a rope from an installation as it
may be very difficult or impossible to replace it.
Identify both ends of the pull rope that in installed within the inclinometer casing. You
will need a length of slack at the access end from the inclinometer casing (red arrow,
Figure 17: Single end installation) of equal length to the inclinometer casing.
I. If using a single ended installation, make sure both ends of the rope
are visible and there is adequate slack at the end of both ends. A
length of the rope equal to the length of the inclinometer casing will
need to be pulled through the inclinometer casing.
NEVER LET THE BLUE
END ENTER TO ROPE
CASING
Access End
Figure 17: Single end installation