32

pH Input (isolated)

pH range: 0 to 14 pH
Isolation: 500 VDC to earth ground

Current and Voltage Input (isolated)

Input range: 4 to 20 mA or 0 to 20 mA

0 to 5 VDC or 0 to 10 VDC

Isolation:

500 VDC to earth ground

2-Relay Output Card

2 SPDT contact outputs 5 A @ 250 VAC or
5A @ 30 VDC maximum

Dual Proportional Output Card

2 SPST contact outputs 5 A @ 250 VAC or
5 A @ 30 VDC maximum

4 to 20 or 0 to 20 mA Output Card

Response time: 2.5 s max. for 100% change
Max. loop resistance: 425 

Isolation: 500 VDC to earth ground (iso. version)

0 to 5 or  0 to 10 VDC Output Card

Response time: 2.5 s max. for 100% change
Min. load resistance: 1 k

Isolation: 500 VDC to earth ground (iso. version)

Accuracy

Display: pH 

±

0.02

Analog output: 

±

0.5% of full scale

Summary of Contents for SIGNET 9030 Intelek-Pro

Page 1: ...GF SIGNET 9030 Intelek Pro Instruction Manual pH Controller GEORGE FISCHER GF...

Page 2: ...CAUTION Remove AC power to unit prior to wiring input and output connections Important Safety Information Remove AC power before opening unit Electrical shock hazard exists...

Page 3: ...10 3 1 Introduction 10 3 2 Calibration Menu pH Sensor Inputs 12 3 3 Calibration Menu Analog Inputs 13 3 4 2 Relay Operation 15 3 5 Dual Proportional Relay Operation 15 3 6 Calibration Menu Relay Outpu...

Page 4: ...anty card Please fill out and return warranty card as soon as possible Warranty Record For your protection record your unit s purchase date and serial number for future reference The serial number dec...

Page 5: ...ventories installed options during power up allowing you to upgrade your system in seconds without the need for additional equipment The unit s front panel features a highly visible 4 5 digit seven se...

Page 6: ...s of optional output alarm relays 1 2 and additional relays 3 4 proportional or on off control Shows pH mV temperature in C and relay activation status information 2 LCD Display A Stores a calibration...

Page 7: ...y 1 COM NO NC contact set for external device control optional 3 RLY1 Alarm relay 2 COM NO NC contact set for external device control optional 4 RLY2 Proportional control relay 4 COM NO contact set fo...

Page 8: ...outdoor and or stand alone installations the splash proof NEMA 4X IP65 back cover kit is recommended ordered separately Figure 1 External dimensions Panel Cutout Instructions Recommended panel cutout...

Page 9: ...1 Jumper selectable for 90 to 132 OR 180 to 264 VAC operation Confirm AC power configuration before applying power See section 4 2 2 A direct or low impedance AC ground earth ground MUST be used for...

Page 10: ...ange of compatibility for most applications pH Input Card Provides isolated pH sensor input capability requiring no internal configuration Analog Input Cards Two analog input options available Analog...

Page 11: ...educe the possibility of noise interference separate AC relay lines from input output lines Figure 4B 2 Wire Transmitter Wiring Note Relay contacts are rated as 5 A 250 VAC or 5 A 30 VDC maximum resis...

Page 12: ...NC contact Refer to Figure 5 pg 7 for further instructions If proportional operation is selected relays 3 and 4 are configured to provide a varying pulse rate to control metering pumps Relay 3 is ded...

Page 13: ...2 are config ured to the rear ANL2 terminals see section 4 4 Prior to connection determine which options are configured to terminals ANL1 and ANL2 as follows 1 Apply power to unit 2 Press ENTER Avail...

Page 14: ...by the instrument i e pH standard pH slope The CAL menu also provides access to the security code and display contrast features The RELAY menu contains all the functions neces sary to control any outp...

Page 15: ...al Relay 3 and 4 Pulse Relay 3 setpoint Relay 3 deviation Relay 3 pulse value Relay 4 setpoint Relay 4 deviation Relay 4 pulse value All menus operate using a standard sequence 1 Press MOD to enable c...

Page 16: ...llow approximately 3 4 minutes for the sensor temperature to stabilize This adjustment is normally needed only at time of new electrode installation It is recommended to perform two point calibration...

Page 17: ...Yes Select next item Yes CAL pH Press to enter minimum pH MOD Normal operation Recall original value MOD No 0 0 0 0 4 m A I S Go to A 3 3 Calibration Menu Analog Inputs 4 to 20 mA option illustrated...

Page 18: ...Press to select pre amp gain unity X1 or X 3 1 G A I N MOD Normal operation Recall original value MOD No ENTER Modify No Yes Repeat Menu Yes CAL pH Press to select personal security code 0000 to 9999...

Page 19: ...pH setpoint of 3 0 cannot have a hysteresis of 4 0 Hysteresis only applies when exiting an alarm condition LO Relay Operation In LO operation the relay is energized when the pH drops below the set po...

Page 20: ...16 The dual proportional relay configuration is primarily designed to control external metering pumps Setpoints deviation ranges and maxi mum pulse rates are selected via the relay menu Setpoint pH va...

Page 21: ...es RELAY pH Press to set relay pH setpoint 0 4 0 0 S E T R L Y 1 MOD Normal operation Recall original value MOD ENTER Modify No Yes Select next item Yes pH Press to set relay hysteresis 0 4 pH maximum...

Page 22: ...iginal value MOD ENTER Modify No Yes Press to set relay deviation must be less than setpoint 0 1 0 0 R L Y 3 D E V MOD Recall original value MOD No Select next item Yes RELAY pH Normal operation ENTER...

Page 23: ...METER MOD Security Code Yes Unlock security code using Select next item Yes pH Normal operation ENTER Recall original value ENTER Modify No Yes Press to select pH value at minimum current output MOD M...

Page 24: ...entering each of the three view only menus each calibra tion parameter is sequentially displayed on the main and lower displays by successively pressing it s corresponding menu key as follows Main vi...

Page 25: ...tronics assembly 5 from the instrument casing See Figure 14 4 Lift upper retainer with adhesive gasket to install remove plug in cards Be sure plug in cards are properly seated in slots before reassem...

Page 26: ...ions Two AC power options are possible 90 to 132 VAC or 180 to 264 VAC Each power option is selectable via internal jumpers on the main pc board Warning Check AC configuration before applying power Fi...

Page 27: ...igured and DO NOT require this procedure This procedure is recommended for input card replacement only The input card introduction mode is accessed by setting an internal dip switch on the main pc boa...

Page 28: ...Controller 14 ISO 13 Ain 9030 Intlek Pro pH Controller 14 ISO 13 Ain 9030 Intlek Pro pH Controller 14 ISO 13 Ain 9030 Intlek Pro pH Controller pH Sensor mV Input Card Wiring Options A or B 4 20 0 20...

Page 29: ...ssing CAL until the lower display reads C Set the GAIN display to X1 To change press MOD mV or TEMP then press ENTER to save 4 Scroll the CAL menu until the 9030 reads Step 3 assumes the security feat...

Page 30: ...YPE 4 0 pH SIMULATION 10 0 pH SIMULATION see Figure 16 step 5 step 8 pH Sensor mV A 3 2720 pH ORP Place pH sensor in Place pH sensor in Input Card Preamplifier Sensor pH 4 0 buffer pH 10 0 buffer 3 90...

Page 31: ...roduction mode sec 4 1 This completes the introduction mode procedure Optional To enable the security feature close dip switch 1 You must now recalibrate your pH system See sections 3 2 3 3 for detail...

Page 32: ...lay card 3 9000 450 3 0 to 10 VDC non isolated 3 9000 450 2 0 to 5 VDC non isolated 3 9000 460 1 Requires configuration 4 to 20 0 to 20 mA isolated See section 4 7 3 9000 460 3 0 to 10 VDC isolated 3...

Page 33: ...igurations Each 4 to 20 0 to 20 mA iso or non iso output card contains jumper selections for it s operation range See instructions below and Figure 19 Placing the blue jumper in the A position configu...

Page 34: ...peration mode 03 Reset reley 3 deviation or setpoint 04 Reset relay 3 maximum pulses or hysteresis 05 Reset relay 4 pulse setpoint or LOW HI operation mode 06 Reset reley 4 deviation or setpoint 07 Re...

Page 35: ...4X IP65 front optional NEMA 4X IP65 rear cover Dimensions 3 5 x 3 5 x 6 5 in 88 x 88 x 165 mm Memory Backup Non volatile RAM Liquid Crystal Display 4 5 digits 0 5 inch high upper 8 digits 0 3 inch hi...

Page 36: ...0 VAC or 5A 30 VDC maximum Dual Proportional Output Card 2 SPST contact outputs 5 A 250 VAC or 5 A 30 VDC maximum 4 to 20 or 0 to 20 mA Output Card Response time 2 5 s max for 100 change Max loop resi...

Page 37: ...f of date of purchase will be required before warranty repairs can begin Transducers and cables will not be covered after installation Parts which prove to be defective in the first year will be repai...

Page 38: ...ircuit configuration These will be incorporated as required in older units on a minimal charge basis while under warranty Consequential Damages Signet Scientific Company shall not be liable for specia...

Page 39: ...Notes...

Page 40: ...Notes...

Page 41: ......

Page 42: ...hi 1 Chome Naniwa Ku Osaka 556 91 Japan Tel 816 648 2545 Fax 816 648 2565 China Georg Fischer Ltd Rm 1503 Business Residence Bldg of Asia Plaza 2 3 Bldg No 5th Qu Anzhenxili Chaoyang Qu Beijing 100029...

Reviews: