background image

 

 


 

 

Warranty Statement 

Geokon, Inc. warrants its products to be free of defects in materials and workmanship, under normal 

use and service for a period of 13 months from date of purchase. If the unit should malfunction, it 

must be returned to the factory for evaluation, freight prepaid. Upon examination by Geokon, if the 

unit is found to be defective, it will be repaired or replaced at no charge. However, the WARRANTY 

is VOID if the unit shows evidence of having been tampered with or shows evidence of being 

damaged as a result of excessive corrosion or current, heat, moisture or vibration, improper 

specification, misapplication, misuse or other operating conditions outside of Geokon's control. 

Components which wear or which are damaged by misuse are not warranted. This includes fuses and 

batteries. 

Geokon manufactures scientific instruments whose misuse is potentially dangerous. The instruments 

are intended to be installed and used only by qualified personnel. There are no warranties except as 

stated herein. There are no other warranties, expressed or implied, including but not limited to the 

implied warranties of merchantability and of fitness for a particular purpose. Geokon, Inc. is not 

responsible for any damages or losses caused to other equipment, whether direct, indirect, incidental, 

special or consequential which the purchaser may experience as a result of the installation or use of 

the product. The buyer's sole remedy for any breach of this agreement by Geokon, Inc. or any breach 

of any warranty by Geokon, Inc. shall not exceed the purchase price paid by the purchaser to Geokon, 

Inc. for the unit or units, or equipment directly affected by such breach. Under no circumstances will 

Geokon reimburse the claimant for loss incurred in removing and/or reinstalling equipment. 

Every precaution for accuracy has been taken in the preparation of manuals and/or software, however, 

Geokon, Inc. neither assumes responsibility for any omissions or errors that may appear nor assumes 

liability for any damages or losses that result from the use of the products in accordance with the 

information contained in the manual or software. 

Summary of Contents for GK-604

Page 1: ...ut the written consent of Geokon Inc The information contained herein is believed to be accurate and reliable However Geokon Inc assumes no responsibility for errors omissions or misinterpretation The...

Page 2: ......

Page 3: ...re are no warranties except as stated herein There are no other warranties expressed or implied including but not limited to the implied warranties of merchantability and of fitness for a particular p...

Page 4: ......

Page 5: ...Using the GK 604 Readout Software 5 2 3 Exiting the Program 8 3 Configuring Holes Probes and Projects 9 3 1 Hole Configuration 9 3 2 Probe Configuration 10 3 3 Project Configuration 10 3 4 Compass Pro...

Page 6: ...eadings Menu 6 Figure 7 Live Readings Screen 6 Figure 8 Save data confirm 7 Figure 9 Auto increment save 7 Figure 10 File Save As Screen 7 Figure 11 Hole Configuration 9 Figure 12 Hole Configuration F...

Page 7: ...on This simplifies the handling of the system in the field as well as simplifying the transfer of data to your PC workstation for final analysis 1 1 Features Rugged general purpose reliable readout ba...

Page 8: ...e familiarize yourself with the Field PC see the included CD Reference Manual and the Windows Mobile OS It is assumed in the instructions below that you can launch applications from the Start button i...

Page 9: ...the remote Read about setting up a Bluetooth partnership in Chapter 9 of the Field PC s Reference Guide Several ways to start the Bluetooth Manager 2 Once in the Bluetooth Settings Manager click on th...

Page 10: ...n will momentarily display the prompt to the right and then return to the Bluetooth Devices screen 6 Click on the COM Ports tab If the Geokon device is already assigned to a COM Port the partnership p...

Page 11: ...t launch the application displays the error shown in figure 3 then the following options should be considered Make sure the remote is turned on blue light blinking Select the System option and Connect...

Page 12: ...rt of a survey the level is set to the Starting Level configured for a particular hole Pressing the Record button with a finger or tap of the stylus records that set of A B values and automatically ch...

Page 13: ...Figure 8 Save data confirm o If Yes is selected you then will be given the choice of saving with the auto increment suffix on the standard filename see figure 9 Selecting Yes again causes the save ope...

Page 14: ...y the remote will time out and shut off This option retains any readings that haven t been saved to a file simply re activate the GK 604 program and pick up where you left off Selecting the Readings E...

Page 15: ...board icon bottom of the screen to bring up the on screen keyboard Use it to edit the Hole ID name 9 Probe Number Select the Probe Number or name from the drop down list This associates a hole with a...

Page 16: ...set of readings you ll see the effect when you go to Live Readings and the readings which are saved in this session OK Tapping OK updates the current session and saves the information to the probe con...

Page 17: ...at a Compass Probe has been selected see figure 16 The software is designed to work only with the Geokon 6005 3 Spiral Indicator Probe Only one channel A is read and displayed on the Live Readings scr...

Page 18: ...have to be transferred are the GTilt data files although archiving the others on a master PC is recommended In either case this is easily accomplished several different ways Connecting the Field PC to...

Page 19: ...field and may require sending the unit back to Geokon With the GK 604 readout software running select System Update Firmware and follow the on screen instructions It takes several minutes to complete...

Reviews: