background image

6

Setting Platen Height

The height adjustment knob on the DK20SP allows for thicker

items to be placed in the press. The factory set height of the press is
the proper platen height setting for most fabrics, and materials under
1/4” thick. Unlike manual presses, the actual amount of pressure on
the DK20SP is determined by the air regulator and air gauge, NOT
by the height of the heat platen. However, if the platen height does
not provide enough clearance for especially thick items, this can be
adjusted.

To raise the heat platen, turn the

pressure knob to the left,
counterclockwise.

The top head will rise away

from the lower table.

To lower the heat platen, turn

the pressure knob to the right,
clockwise.

The top head will lower toward

the pressing table.

Actuating the Press

To actuate the machine,

simply press both black buttons
together. This will cause the air
bladder to fill, the table to raise,
and the work to be pressed. The
digital timer will automatically
begin cycling. At the end of the
timer cycle the press will
automatically release and the
timer will reset to the preset time. BOTH black buttons must be
pressed together, to insure that both operators hands are clear of the
pressing area, for safety purposes.

To interrupt the timing cycle, in order to do a quick pre-press or

press for a shorter period of time than is set, simply press both black
buttons together again. For emergency one-hand release of the air
pressure, press the middle button on the front panel.

Summary of Contents for Digital Knight DK20SP

Page 1: ...1 Digital Knight 16x20 Automatic Digital Swinger...

Page 2: ...laten Height 6 Actuating the Press 6 Guidelines Standard Settings 7 Programmable Presets 8 User Options Menu 9 Fahrenheit Celsius 9 Timer Counter 9 Recorded Pressings 9 Pressure Height Gauge Settings...

Page 3: ...much time and effort in using this press and in your heat pressing applications Throughout this manual many areas and components of this machine will be referred to by specific names Please refer to t...

Page 4: ...s editable in the default operating mode of the controller The left two digits of the time display are minutes The right two digits are seconds This can be changed to Hours Minutes in the User Options...

Page 5: ...ange of the controller is from 150 F to 550 F 65 C to 288 C During the first heat up cycle of the press the controller will display 150 F 65 C until the heat platen temperature rises above that temper...

Page 6: ...r the heat platen turn the pressure knob to the right clockwise The top head will lower toward the pressing table Actuating the Press To actuate the machine simply press both black buttons together Th...

Page 7: ...reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfer i...

Page 8: ...based on the best results for every application When those presets are selected the user is immediately returned to the proper settings without time consuming experimentation and risk of unsuccessful...

Page 9: ...renheit Celsius The Current Set Point and Preset temperature values can be displayed in Fahrenheit or Celsius To change the value to F or C use the arrow keys Press PRG to move to the next menu item T...

Page 10: ...results of the transfer begin to deteriorate the Drop Sense feature can help the user avoid this Use the arrow keys to set the degrees or to turn this feature off If the Current temperature drops belo...

Page 11: ...ing cycle as well as if the Drop Sense feature is enabled Use the arrow keys to change the values or to turn the alarm off Please note the different alarms below denotes a short beep _ denotes a longe...

Page 12: ...he silver colored ring around the post that stops the head from continually swinging over the table It can be loosened and retightened when the correct position is obtained Q The control displays Err...

Page 13: ...the way over the table and the rear limit micro switch is not being closed the press will not activate If all of these check points have been tried and the digital control is counting down but the pr...

Page 14: ...on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its return If a press covered by the one year limited warranty mu...

Page 15: ...15...

Page 16: ...16...

Reviews: