Genvex Optima 100 Design Operating Instructions Manual Download Page 7

7

Subject to technical modifications of Optima 100

6 months

Hold the button B4 down for more than 10 seconds, until 

LED D1 begins to flash.

Then press button B5 five times until LED D2/D5 begin to 

flash. Then press button B4 to confirm the setting and to 

return to the main display.

NB: If there is a filter alarm, the filter timer 

cannot be set. The filter timer must be reset 

first, before, it can be set again.

3.4. Bypass

Systems that are supplied with a bypass can operate in a 

so-called summertime mode. The outlet air is let outside 

the heat recovery circuit in the unit via a valve, so that 

there is no heat recovery. The temperature of the air that 

is let into the house is, thus, not heated, but corresponds 

with the temperature of the air outside.

The bypass function must be manually activated via the 

display. This is done as per the following:

Bypass ON:

Do a short press on button B5, so LED D5 stays on.

Bypass OFF:

If LED D5 is constantly on, do a short press on button 

B5 until D5 turns off. Bypass is OFF, if LED D5 is not 

constantly on.

3.5 Electrical Heating

Electrical heating can either be accomplished by a pre-

heating or post-heating element.

A pre-heating element  ensures that the heat recovery 

circuit does not freeze with very low outdoor air 

temperatures.

A post-heating element further heats the inlet air after 

it has been heated via the heat recovery process in the 

system.

The heating element must be activated manually via the 

display. This is done as per the following:

To activate the menu, hold the button B5 down for more 

than 10 seconds, until LED D1 begins to flash or the LEDs 

D1/D2 flash at the same time.

Electrical heating ON:  

LEDs D1/D2 flash at the same time

Electrical heating OFF:

  

LED D1 flashes

Press button B5 for a short period to change between ON 

and OFF. 

Press button B4 to return to the main menu.

3.6 Restoring the factory settings

If the set points that are installed result in the system not 

operating as expected, and the cause cannot be found, 

the factory settings can be restored as follows:

During start-up of the system hold B4 down so that all 

five LEDs are flashing. As soon as all five LEDs stay 

constantly on, the button B4 can be released, and the 

system’s factory settings are restored.

3.7 Set points´ table

Text:

Factory 

settings:

Installed 

settings

1

Inlet airflow rate 1 (0-100%)

25

2  

Inlet airflow rate  2 (0-100%)

50

3

Inlet airflow rate  3 (0-100%)

75

4

Outlet airflow rate  1 (0-100%)

25

5  

Outlet airflow rate  2 (0-100%)

50

6

Outlet airflow rate  3 (0-100%)

75

7

System Stop

OFF

8

Timer level 4

OFF

9

Timer level 4

3

10 Filter change

3

11 Filter stop

OFF

12 Frost protection

ON

14 Frost protection

1

15 Extra heating

OFF

16 Extra heating

0

17 Menu On

ON

Hard-coded:

Level 4 inlet, 100%

Level 4 outlet, 100%

Hygrostat, as per Optima 250. 

Summary of Contents for Optima 100 Design

Page 1: ...Genvex A S Sverigesvej 6 DK 6100 Haderslev Tlf 45 7353 2700 www genvex dk O R IGIN A L w w w genvex d k Optima 100 Opus Optima 100 Design Version 2012 02 28 Operating instructions uK ...

Page 2: ...3 Operation 5 3 1 Use and changing of the settings 5 3 2 Ventilator Speed 5 3 3 Filter alarm 6 3 4 Bypass 7 3 5 Electrical Heating 7 3 6 Restoring the factory settings 8 3 7 Set points table 8 4 Function 8 4 1 Extra capacity 8 5 Maintenance 9 5 1 Parts 9 5 2 Alarms 9 5 3 Demounting taking the system out of operation 9 6 Troubleshooting 10 6 1 System does not operate 10 6 2 Fault on the air side 10...

Page 3: ...int Support Point Underneath the control panel there is an access for the A Terminal block Connection to main circuit board A low current cable 8 x 0 25 mm2 must be attached between the unit and the control panel 50 m is the maximum cable length The voltage drop for cable lengths over 50 m is too high and can result in unreliable operation How to mount the wall fixture First screw the fixture secu...

Page 4: ...d to hold both buttons down i e B3 and B5 together 3 Operation All Genvex GE S Energy and GEU residential ventilation units can be operated with the Optima 100 control The Optima 100 control has the following settings Ventilator speed filter alarm bypass ON OFF and electrical heating ON OFF The control unit is supplied with factory set settings that enable the unit to be operated without initially...

Page 5: ...1 To return to the main display press button B4 repeatedly until all of the LED s stop flashing Level 2 outlet airflow Level 2 is the recommended operating level for an optimal indoor climate and should be commissioned to meet the building s ventilation requirements To access level 2 from the main display hold down button B3 for more than 10 seconds until LED D1 begins to flash Press button B4 onc...

Page 6: ...e unit has operated since the last filter replacement The filter timer can be set between 1 6 which corresponds with 1 6 months It is recommended to initially set the filter timer to 3 corresponding to 3 months If the filters become too dirty during the set period you can set the filter timer to a lower number of months On the other hand if the filters do not require replacement at the end of the ...

Page 7: ...ing element further heats the inlet air after it has been heated via the heat recovery process in the system The heating element must be activated manually via the display This is done as per the following To activate the menu hold the button B5 down for more than 10 seconds until LED D1 begins to flash or the LEDs D1 D2 flash at the same time Electrical heating ON LEDs D1 D2 flash at the same tim...

Page 8: ...utlet must be checked for blockages and the water trap must be checked for water in association with changing filters before autumn begins Pour 1 liter of water in the condensation water tray and see if the water drains freely If the condensation outlet does not work there is a risk of water damage in the building Ventilators Remember to turn off the power before inspecting the unit The fan impell...

Page 9: ... condensation on the ground due to frost The outlet is not sufficiently protected against frost 6 2 Fault on the air side No inlet air to residence s rooms Fault Defective ventilator Blocked filter Dirt and leaves in the fresh air vent in Autumn or snow and ice in Winter Control circuit fuse has blown No outlet air from wet rooms Fault Defective ventilator Blocked filter Exhaust vent roof cap is b...

Page 10: ... Green Brown Brown Blue Blue Blue Blue Blue Yellow Yellow Yellow Red 5V GND 5V 1 2 1 2 L1 1 2 3 1 2 3 1 2 3 4 1 2 3 4 L2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L3 1 2 1 2 H1 1 2 1 2 H3 1 2 1 2 H7 1 2 3 1 2 3 H8 1 2 1 2 H9 L1 M1 M2 M4 N PE PE PE T1 90 C manu PE PE L L N N PE PE T4 T9 M1 M2 1 2 3 4 1 2 3 4 L6 1 5 6 7 8 5 6 7 8 L6 2 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 4 4 4 4 5 5 5 6 6 7 7 8 8...

Page 11: ...11 Subject to technical modifications of Optima 100 ...

Page 12: ...ium Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Ireland ECO Systems Ireland Ltd Co Antrim BT54 6PH Tel UK 028 ROI 048 44 2076 8708 Fax UK 028 ROI 048 44 2076 9781 E Mail info ecosystemsireland com Croatia Pichler CO d o o 10000 Zagreb Tel 385 0 1 65 45 407 Fax 385 0 1 65 45 409 E Mail pichler zg hnet hr Slovenia Pichler CO d o o 2000 Maribor Tel 3...

Reviews: