background image

Version 1,0 / 1206

Installations Manual

.

 

Activ Ventilation

 

Heating pump

 .

GE 315 VP (C)

 .

GE 420 VP (C)

 .

GE 525 VP (C)

 

.

GE 630 VP (C)

 .

GE 840 VP (C)

Summary of Contents for GE 315 VP

Page 1: ...Version 1 0 1206 Installations Manual Activ Ventilation Heating pump GE 315 VP C GE 420 VP C GE 525 VP C GE 630 VP C GE 840 VP C...

Page 2: ...n cold loft spaces 6 Insulation of ducts in heated spaces 7 Electrical installation 7 Optimum initial adjustment of plant 8 Maintenance of plant 8 Fault finding 10 Electrical diagram GE 315 630VP VPC...

Page 3: ...ture drops below 2C IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT 100 mm Extract air Fresh air Supply air Exhaust air 7 For inside outlet Siphon A...

Page 4: ...w access for service and maintenance there must be a clear space of a minimum of 600 mm in front of the unit If the unit is located in the loft there must be free access to the unit from the loft hatc...

Page 5: ...is recommended that the duct system is executed in spiral ducting connected with rubber ring seal fittings in order to provide a leak free and durable duct system To achieve a satisfactory low sound...

Page 6: ...make it impossible to secure the condensate drain pipe from freezing by insulation it will be necessary to mount a thermostat controlled heating tape round the condensate drain pipe Insulation of duct...

Page 7: ...0 m Inspection and initial adjustment of appliance To achieve optimum running of the unit it must be initially adjusted with air measuring equipment To start up the unit before adjustment do as follow...

Page 8: ...panel Remove the front cover and take out the bag filter and flat filter The bag filter may be cleaned two or three times with a vacuum cleaner before replacing it The flat filter can be taken out of...

Page 9: ...Fans Every three years check the two fan wheels for dirt If they are dirty they may be cleaned with a brush bottle washer etc Supply and extract valves Clean the valves by wiping with a dry cloth Make...

Page 10: ...ply air to living rooms Error Defective fan Blocked bag filter Fresh air grill blocked by dirt and leaves in the autumn or snow and ice in the winter Fuse on control circuit board has blown No extract...

Page 11: ...Motor Valve 24 VDC 0V 0 10V El heater 1 2 Kw Step1 Relay 2 Extra Cooling Upstream Coil 0 8 KW Relay 3 Magnetic valve Defrosting Relay 4 Relay outlet For extra print For El heater Step 2 Relay 5 Compre...

Page 12: ...RX Motor Valve 24 VDC 0V 0 10V Electric reheater 1 2 Kw Step 1 Relay 2 Extra cooling Preheater 0 8 KW Relay 3 Valve Defrost Relay 4 Relay out for extra board For electric reheater Step 2 Relay 5 Compr...

Page 13: ...ons 13 Electric Diagram GE 840 VP C L1 N PE Start Run Compressor 230VAC 50Hz 7 9A 1502W Mains 1x230VAC 50Hz MAX FUSE 16A Must be connected to ground K CI 9 1 2 3 4 5 6 C PE S R L1 N PE 1 2 4 5 1 2 BLU...

Page 14: ...14 Subject to Technical Modifications EU Declaration of conformity...

Page 15: ...Subject to Technical Modifications 15...

Page 16: ...etikon Tel 41 0 52 355 11 00 Fax 41 0 52 355 11 05 E Mail info sm heag ch 6 Tyskland Deutschland Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info...

Reviews: