44
Mute
All
Combined
All
Separate
1 + 2
3 + 4
1 + 2 + 3
4
VOLUME
Control
Status
Room Combining
All Separate
All Combined
1 + 2 : 3 + 4
1 + 2 + 3 : 4
Status
+5VDC
LED
Status
+5VDC
LED
Status
+5VDC
LED
Status
+5VDC
LED
Volume
Up
Volume
Down
Mute
Control
Status
Status
+5VDC
LED
Room-Combining Controls
Controls for Each Room
Figure 35. Room Combining Using
Control/Status Pins
Any valid function of all XAP 800s connected to the Expansion Bus is capable of
being controlled from the control/status pins of any connected XAP 800. These
functions include volume up, volume down, mute, etc. In addition, pins can be
programmed to call up to 32 preprogrammed presets (each preset representing a
programmed configuration). Thus, routing, level control, AGC, equalization, etc. can
instantly be changed or “reconfigured” by presets.
An example of a useful preset would be in room combining where the room
configuration needs to change on the fly. Wall buttons can be used to activate
presets. Refer to the Hotel/Convention Center Application Example on page 32.
User Definable Control and Status Pins
Most of the pins on the control/status connectors can be programmed to
perform any function—they are user definable. However, these pins come
preprogrammed with defaults. There are some pins that are not user definable.
The table on the following page outlines the pin configurations.