69
IT
MANUALE ISTRUZIONI
Rev. 01_05_2018
Serie Clinic 3
INSTRUCTION MANUAL
EN
MAN_CNC3_A001
SISTEMA DI ESSICCAZIONE DRY TEC - SCHEDA DATI
DRY TEC DRYING SYSTEM - DATA SHEET
SERVIZIO: ......................................................................
FRQWLQXRFRQWLQXRXVRUHKRXUV
SERVICE:
PORTATA ARIA COMPRESSA IN INGRESSO: ................................................................145 sl/min.
INPUT COMPRESSED AIR FLOW RATE:
PORTATA UTILE ARIA COMPRESSA IN USCITA: ............................................................123 sl/min.
OUTPUT COMPRESSED AIR USEFUL FLOW RATE:
TEMPERATURA INGRESSO ARIA COMPRESSA: ................................................. da +2°C a +60°C
COMPRESSED AIR INPUT TEMPERATURE:
PRESSIONE NOMINALE DI ALIMENTAZIONE: ........................................................................ 7 bar
SUPPLY RATED PRESSURE:
PUNTO DI RUGIADA A VALLA ESSICCATORE TEMPERATURA DI PROGETTO:...................
&
DEW POINT DOWNSTREAM FROM DRYER PROJECT:
TEMPERATURA DI PROGETTO: ........................................................................... da +2°C a +60°C
PROJECT TEMPERATURE:
PRESSIONE DI PROGETTO: ...........................................................................................
PD[EDU
PROJECT PRESSURE:
INSTALLAZIONE: ....................................................................................................interna/internal
INSTALLATION:
&2',&(',&26758=,21(48$/,7$·
..................................................................... ISO9001:2008
48$/,7<&216758&7,21&2'(
FLUIDO:
FLUID:
$ULDFRPSUHVVDJHQHUDWDGDFRPSUHVVRUHQRQOXEULÀFDWR
&RPSUHVVHGDLUJHQHUDWHGE\QRQOXEULFDWHGFRPSUHVVRU
6DWXUDGLYDSRUHDFTXHR
6DWXUDWHGZLWKZDWHUYDSRXU
Esente pulsazioni
No pulses
*(17,/,165/7HFKQLFDOGHSW