Genquip Gi2000 Digital Inverter Petrol Generator

Air Filter

 It is very important to maintain an air fi lter in proper condition.
Damage to the generator may arise if the fi lter has:

•  Improperly been serviced.

•  Dirt and other foreign elements adhering to the fi lter due to improper installation and 
engine wear.

NOTE:

 ALWAYS keep the fi lter clean at all times.

Fuel Tank Filter

1. 

Remove the fuel tank cap and fi lter.

2.  Clean the fi lter with solvent, if damaged, replace.

3.  Wipe the fi lter and insert it.

WARNING:

  Be sure the tank cap is securely tightened.

Air Filter Maintainence

1.  Remove side cover.

2. Unscrew 

bolts.

3.  Remove air fi lter cover.

4.  Remove foam air fi lter.

5. Clean 

fi lter in foam fi lter cleaner or kerosene and dry.

6.  Re-oil with fi lter oil.

7.  Squeeze out excess oil do not wring out.

8. Refi t to machine and reassemble.

Summary of Contents for Gi2000

Page 1: ...page 1 Genquip Gi2000 Digital Inverter Petrol Generator Genquip Gi2000 Digital Inverter Petrol Generator Owners Manual...

Page 2: ...page 2 Genquip Gi2000 Digital Inverter Petrol Generator Notes...

Page 3: ...Maintenance 8 Spark Plugs 9 Engine Oil Replacement 10 Air Filter 11 Fuel Tank Filter 11 Genquip Safety 12 Operating Procedure 13 Visual Inspection Start Up Shutdown Potential Hazards 14 15 and Risk As...

Page 4: ...5 Front Side Maintenance Cover 6 Recoil Starter 7 Engine Switch 8 Fuel Drain Hose 1 9 Fuel Drain Hose 2 10 240 Volt Sockets 11 Carry Handles 12 DC Circuit Protector 13 DC Socket 14 Fuel Saver Switch...

Page 5: ...d the fuel tank capacity is 4 litres Check the Fuel Level 1 Make sure the generator is turned off by rotating the engine switch 7 to the off position Fig D 2 Check the fuel by a visual check Remove th...

Page 6: ...m If the oil level falls below the safe operating level the engine will stop automatically Unless you re ll with oil the engine will not start again Note If the engine stalls or does not start turn th...

Page 7: ...To start a cold engine move the choke lever to the start position In order to restart a warm engine leave the choke lever in the run position Fig I 5 Slowly pull the recoil starter 6 until you feel i...

Page 8: ...ster Screen Recoil Starter Check operation Choke Handle Check operation Fuel System Check hose condition look for leaks Fittings Fasteners Check and Tighten Cooling System Air Check for obstructions E...

Page 9: ...eposits using a wire brush 7 Check for discolouration of the top of the spark plug The standard colour should be tan colour 8 Check the spark plug gap Fig V Acceptable gap should be between 0 6mm 0 7m...

Page 10: ...the oil ller neck 5 Once emptied tilt the generator back up and place into the generator up right position 6 Re ll with recommended oil Fill to the upper limit of the ller neck Fig W NOTE The recomme...

Page 11: ...gine wear NOTE ALWAYS keep the lter clean at all times Fuel Tank Filter 1 Remove the fuel tank cap and lter 2 Clean the lter with solvent if damaged replace 3 Wipe the lter and insert it WARNING Be su...

Page 12: ...r in a well ventilated area Keep all ammable materials and fuel away from the operating generator Caution of the hot exhaust must be observed as a generator can easily start a re always locates your g...

Page 13: ...el level Air lter is not dusted and is free of debris Generator grounded Fuel cap on Start up Disconnect any electrical devices from the generator Generator is on a level surface Exhaust is free from...

Page 14: ...n fuel cap slowly Do not over ll fuel tank If fuel spillage has occurred during refueling clean the spillage completely and allow suf cient time for any fuel vapors to dissipate Tampering with the fac...

Page 15: ...Electrocution 1 Never operate the generator whilst wet or expose to damp conditions Clean the generator only when shut down and cooled down completely Do not spray water directly on or near any electr...

Page 16: ...pressure air or vacuum system CAUTION DO NOT use a forceful spray of water to clean the generator Water can penetrate generator s electrical system which could reduce insulation resistance Possible g...

Page 17: ...1600 Watts MAX OUTPUT 2000 Watts RUN TIME AT 1 2 RATED LOAD 7 hours RUN TIME AT RATED LOAD 4 5 hours RATED VOLTAGE 240 V RATED FREQUENCY 50 Hz RATED CURRENT 7A DC OUTPUT 12V 8A ENGINE TYPE 158F OHV A...

Page 18: ...om the carburettor by loosening the drain screw on the carburettor oat chamber 3 Turn the fuel cock lever to OFF Start the engine and leave it run until it stops This will burn any remaining fuel in t...

Page 19: ...may be ooded Leave the generator rest for 5 10 minutes and then try again following the instructions when doing so Alternatively if the choke lever is in full choke position start switch the choke to...

Page 20: ...lied DC cables with the actual generator Mixed polarity Check to make sure that the DC cables are connected to the correct battery polarity terminals That is positive to positive and negative to negat...

Page 21: ...sition Generator air lter may need cleaning Remove the air lter Check to make sure that the air lter is clean If required clean dry and re install the air lter Generator fuel lter may be blocked The i...

Page 22: ...e caused by use of alternate or contaminated fuel 4 Damage to equipment caused by excessive vibration 5 Damage to engine due to surging from allowing fuel to run out 6 Damage to engine parts caused by...

Page 23: ...page 23 Genquip Gi2000 Digital Inverter Petrol Generator Notes...

Page 24: ...page 24 Genquip Gi2000 Digital Inverter Petrol Generator www genquip com au Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call 1300 730 716...

Reviews: