background image

SPIN 3 - SPIN 4 - SPIN 424 - SPIN 6

ENGLISH

Guide for the installer

Page 8

9.3. END FOOT

The end foot, fig. 21, makes it possible to rest the bar when closing, thus 

avoiding any downward bending of the bar.

  Use of the foot involves adapting of the balance spring..

9.4. FORK SUPPORT

The fork support, fig. 22, is used for two purposes:

• 

to avoid that the bar, when in closing position, bends or breaks under 

the effect of outside forces.

• 

to make it possible to rest the bar in closing position, thus avoiding any 

downward bending of the bar.

  Use of the fork support does not require changes to the balance 

spring.

9.4.1. P

osItIonIng

 

the

 

fork

 

suPPort

To position the fork support foundation plate, refer to the measurements 

shown in fig. 23 where:

 

L= bar length

 

A= L-500mm

 

For correct positioning, we recommend positioning the fork support 

after having completely installed the automated system. The result 

will be correct positioning of the fork centre with the centre of the 

bar.

9.5. BAR LIGHT KIT

For SPIN 3 and 4 models, a light kit is available for use on the top of the 

bar. The lights increase bar visibility, especially at night.

  Installation of the light kit involves adapting of the balance spring.

9.6. BATTERY KIT

For the SPIN 424 model, an emergency battery kit is available for 

positioning inside the upright. The battery kit makes it possible to make 

up for electrical power interruptions.

  The battery kit cannot be used as an alternative to electrical 

power.

Summary of Contents for SPIN 3

Page 1: ...SPIN GUIda per l installatore Guide for the installer Guide pour l installateur Gu a para el instalador Leitfaden f r den Installateur Gids voor de installateur...

Page 2: ...any danger areas against mechanical movement Risks such as crushing dragging and shearing 17 Use of at least one indicator light is recommended for every system as well as a warning sign adequately s...

Page 3: ...ILABLE ACCESSORIES page 8 9 1 SKIRT KIT page 8 9 2 ARTICULATION KIT page 8 9 3 END FOOT page 8 9 4 FORK SUPPORT page 8 9 5 BAR LIGHT KIT page 8 9 6 BATTERY KIT page 8 CE DECLARATION OF CONFORMITY DIRE...

Page 4: ...be used with bars longer than 6 metres applied to SPIN 6 models 2 ELECTRICAL PREPARATIONS standard system Fig 2 Pos Description Cable diameters a Operator electrical power supply 3x1 5mm2 b TX photoc...

Page 5: ...spring is correctly tensioned when it is able to keep the bar steady once it is at 45 8 Tighten the tie rod lock nut and secure everything 9 Restore normal operation as described in paragraph 5 4 STA...

Page 6: ...support To position the fork support foundation plate refer to the measurements shown in fig 23 where L bar length A L 500mm For correct positioning we recommend positioning the fork support after ha...

Page 7: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 01 Fig 03 Fig 02 Fig 05 Fig 04...

Page 8: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 07 Fig 06 Fig 10 Fig 08 Fig 09 Fig 12 Fig 11...

Page 9: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 3 Fig 14 Fig 13 Fig 17 Fig 15 Fig 16 Fig 19 Fig 18...

Page 10: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 4 Fig 21 Fig 20 Fig 23 Fig 22...

Page 11: ...SPIN GUIDA per l UTENTE USER s GUIDE INSTRUCTIONS POUR L UTILISATEUR Gu a para el Usuario F h rer f r den Benutzer Handleiding voor de gebruiker...

Page 12: ...bar be required due to electrical power cut off or inefficiency of the automated system proceed as follows 1 Cut off power to the system using the differential switch located upstream from the system...

Page 13: ...ng 1 Velligheldsvoorziening 1 Dispositivo di sicurezza 2 Safety device 2 dispositif de s curit 2 Dispositivo de seguridad 2 Scherheltsvor richtung 1 Velligheldsvoorziening 2 Coppia di fotocellule 1 Pa...

Page 14: ...chnicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 4 Tecnico Technicia Technicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 5 Tecnico Techni...

Page 15: ...Anlage wird der Einsatz von mindestens einem Leuchtsignal empfohlen sowie eines Hinweisschildes das ber eine entsprechende Befestigung mit dem Aufbau des Tors verbunden wird Dar ber hinaus sind die u...

Page 16: ...FAAC S p A Via Calari 10 40069 Zola Predosa BOLOGNA ITALIA Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com 00058I0219 Rev 5...

Reviews: