background image

SPIN 3 - SPIN 4 - SPIN 424 - SPIN 6

ENGLISH

Instructions for use

Page 3

  Before using the product, read the instructions carefully. Keep 

these instructions for future reference.

We thank you for having chosen one of our products. GENIUS is certain 

that from it you will obtain all the performance you require. All our products 

are the result of years of experience in the field of automated systems, with 

the added advantage of being part of one of the sector’s leading groups.

GENERAL SAFETY REGULATIONS

The  

SPIN

, automated system, if correctly installed and used, guarantees 

a high level of safety. A few simple behaviour rules can avoid accidental 

inconveniences:

• 

Do not pass while the bar is moving. Before passing, wait for the bar 

to open completely.

• 

Never stop under the bar.

• 

The automated system must not be used by children, persons with 

limited physical, mental and sensory capacities or persons lacking 

experience or the necessary training.

• 

Do not allow children to play with the automated system.

• 

Do not voluntarily prevent movement of the bar.

• 

Do not allow branches or bushes to interfere with movement of the bar.

• Ensure that the system visual signals are kept efficient and in perfect 

view.

• 

Do not attempt to manually operate the bar unless it has been released.

• 

In case of malfunction, cut off the power, release the bar to allow access 

and wait for the technical intervention of qualified personnel.

• 

Once manual operation is prepared for, before restoring normal 

operation, ensure that power to the system is cut off.

• 

Do not modify any of the automated system components.

• 

Every six months, check to ensure that the automated system is 

operating correctly.

• 

Avoid any attempt to repair or service the system, and contact only 

qualified GENIUS personnel or GENIUS service centres.

• Ensure that the installation technician fills in the enclosed maintenance 

record

MANUAL OPERATION

Should manual operation of the bar be required due to electrical power 

cut-off or inefficiency of the automated system, proceed as follows:

1. 

Cut off power to the system using the differential switch located 

upstream from the system.

2. 

Open the door.

3. 

Insert the release key, fig. 1, ref. 

a

, in the release device opening.

4. 

Turn the key anti-clockwise until the mechanical stop is reached.

  The mechanical stop consists of a pin, fig. 2 ref. 

a

. Do not go 

beyond it to avoid compromising system operation.

5. 

Manually move the bar, in both directions, until release of the locking 

device can be felt.

  If the automated system must stay released: 

• remove the release key and close the door

 

• do not restore power to the system.

RESTORING NORMAL OPERATION

To restore normal operating conditions, proceed as follows:

1. 

Ensure that the system is powered down.

2. 

Open the door using the provided key.

3. 

Insert the release key, fig. 3, ref. 

a

, in the corresponding opening.

4. 

Turn the release key clockwise until it rests against the shaft, fig. 3.

5. 

Once the key is resting against the shaft, move the bar manually until 

insertion of the release device is felt.

  Once the key is resting against the shaft, do not go further to 

avoid compromising operation of the device.

  If  turning  of  the  release  key  becomes  excessively  difficult 

and the key is still not resting against the shaft, try moving 

the bar manually until insertion of the release device is felt.

 

Then continue turning the key until it is resting against the 

shaft.

6. 

Close the door again, ensuring that the earth cable connection between 

the door and the upright is intact.

7. 

Restore power to the system.

8. 

Ensure that the automated system is operating correctly.

MAINTENANCE

To ensure correct operation and a constant safety level over time, every 

six months have the overall system checked paying special attention to 

safety devices. 

  All automated system maintenance operations must be carried 

out  by  qualified  GENIUS  personnel  or  GENIUS  service 

centres.

REPAIRS

The end user must avoid any attempt to repair or service the system, 

and must contact only qualified GENIUS personnel or GENIUS service 

centres.

Summary of Contents for SPIN 3

Page 1: ...SPIN GUIda per l installatore Guide for the installer Guide pour l installateur Gu a para el instalador Leitfaden f r den Installateur Gids voor de installateur...

Page 2: ...any danger areas against mechanical movement Risks such as crushing dragging and shearing 17 Use of at least one indicator light is recommended for every system as well as a warning sign adequately s...

Page 3: ...ILABLE ACCESSORIES page 8 9 1 SKIRT KIT page 8 9 2 ARTICULATION KIT page 8 9 3 END FOOT page 8 9 4 FORK SUPPORT page 8 9 5 BAR LIGHT KIT page 8 9 6 BATTERY KIT page 8 CE DECLARATION OF CONFORMITY DIRE...

Page 4: ...be used with bars longer than 6 metres applied to SPIN 6 models 2 ELECTRICAL PREPARATIONS standard system Fig 2 Pos Description Cable diameters a Operator electrical power supply 3x1 5mm2 b TX photoc...

Page 5: ...spring is correctly tensioned when it is able to keep the bar steady once it is at 45 8 Tighten the tie rod lock nut and secure everything 9 Restore normal operation as described in paragraph 5 4 STA...

Page 6: ...support To position the fork support foundation plate refer to the measurements shown in fig 23 where L bar length A L 500mm For correct positioning we recommend positioning the fork support after ha...

Page 7: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 01 Fig 03 Fig 02 Fig 05 Fig 04...

Page 8: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 07 Fig 06 Fig 10 Fig 08 Fig 09 Fig 12 Fig 11...

Page 9: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 3 Fig 14 Fig 13 Fig 17 Fig 15 Fig 16 Fig 19 Fig 18...

Page 10: ...SPIN 3 SPIN 4 SPIN 424 SPIN 6 Immagini Images Images Im genes Bilder Afbeeldingen Pag 4 Fig 21 Fig 20 Fig 23 Fig 22...

Page 11: ...SPIN GUIDA per l UTENTE USER s GUIDE INSTRUCTIONS POUR L UTILISATEUR Gu a para el Usuario F h rer f r den Benutzer Handleiding voor de gebruiker...

Page 12: ...bar be required due to electrical power cut off or inefficiency of the automated system proceed as follows 1 Cut off power to the system using the differential switch located upstream from the system...

Page 13: ...ng 1 Velligheldsvoorziening 1 Dispositivo di sicurezza 2 Safety device 2 dispositif de s curit 2 Dispositivo de seguridad 2 Scherheltsvor richtung 1 Velligheldsvoorziening 2 Coppia di fotocellule 1 Pa...

Page 14: ...chnicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 4 Tecnico Technicia Technicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 5 Tecnico Techni...

Page 15: ...Anlage wird der Einsatz von mindestens einem Leuchtsignal empfohlen sowie eines Hinweisschildes das ber eine entsprechende Befestigung mit dem Aufbau des Tors verbunden wird Dar ber hinaus sind die u...

Page 16: ...FAAC S p A Via Calari 10 40069 Zola Predosa BOLOGNA ITALIA Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com 00058I0219 Rev 5...

Reviews: