![Genius INTERM0D02 433 Manual Download Page 4](http://html1.mh-extra.com/html/genius/interm0d02-433/interm0d02-433_manual_2212741004.webp)
00058I0761 - Rev. 3
2
INTERMODO2
70
32,5
90
105
98
1
4
2
3
DL1
SW1
SW2
DL2
CH1
CH2
5
DL3
6
7
8
10
11
12
+
9
1 2
N.O.
N.O.
DS1
ENGLISH
Preperforated facility for cable grippers
Cover
Facility for securing on DIN guide
Fittings for screw securing
Terminals for command output (N.O.)
Normally open (N.O.) relay contact
Signalling LEDs (ON= OUTPUT ACTIVE)
DL1=LED CH 1
DL2=LED CH2
Radio programming push-buttons
SW1=PUSH-BUTTON CH1 SW2=PUSH-BUTTON CH2
DS1:
Selection dip-switch
Power supply terminal
Terminal for antenna
DL3: Mains ON LED ( ON = MAINS PRESENT )
Fig.1
DS1
ON
OFF
DIP
SWITCH
1
OUTPUT
CHANNEL 2
STEP-BY-STEP
OUTPUT
CHANNEL 2
PULSED
DIP
SWITCH
2
NOT USED
NOT USED
INTERMODO2 433 - INTERMODO2 868
1. DESCRIPTION
The
INTERMODO2
control board is a two-channel external receiver, which has an integrated decoding system (JLC, RC). When a channel
is activated by radio control (JLC, RC), the relevant N.O. relay contact closes by the methods described in chapter 5.
The selectable configurations are:
CH1 = pulsed N.O. relay output
CH2 = pulsed/step-by-step N.O relay output (selectable by DS1)
2. TECHNICAL SPECIFICATIONS
INTERMODO2 433
INTERMODO2 868
POWER SUPPLY (V)
12/24 V~ / V
"
RECEPTION FREQUENCY (MHz)
433.92±0.1
868.35±0.2
ABSORBED CURRENT (A)
100 mA
DECODING
RC-JLC
JLC
SAVEABLE CODES
250
NUMBER OF CHANNELS
2
NUMBER OF RELAY OUTPUTS (N.O.)
N 1 pulsed (CH1)
N 1 pulsed/step-by-step (selectable) (CH2)
RELAY CONTACTS CAPACITY
0.5 A / 24 V
PROTECTION CLASS
IP 44
OPERATING AMBIENT TEMPERATURE (°C)
-20 / +55