Code
Problem
Cause
Solution
FAULT CODES
611
COP Failure
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
612
Invalid Interrupt
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
613
A/D Loss
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
614
RTI 1 Loss
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
615
Flash Checksum
Invalid
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
616
RAM Failure
Loose wire connections to
ECM OR ECM is faulty.
Locate and repair any engine
harness wiring damage or
shorts to ECM to be sure they
are secure OR replace ECM.
631
External 5V DC Ref
Lower than Expected
Engine harness wiring and/or
connections open or shorted to
ground OR there is a faulty
engine sensor OR ECM is
faulty.
Locate and repair any engine
harness wiring damage or
shorts OR locate and
troubleshoot or repair faulty
engine sensor OR replace
ECM.
Summary of Contents for Z-60/34
Page 12: ...Genie Z 60 34 Part No 75861 November 2003 This page intentionally left blank ...
Page 157: ......
Page 160: ...Electrical Schematic Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 162: ...Ground Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 164: ...Platform Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 165: ......
Page 168: ...Electrical Schematic Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Page 170: ...Ground Control Box Wiring Diagram Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Page 173: ...November2003 Section 6 Schematics PartNo 75861 GenieZ 60 34 6 11 ...
Page 176: ...Hydraulic Schematic 2WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Page 178: ...Hydraulic Schematic 4WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Page 180: ...Hydraulic Schematic 2WD Models after serial number 4460 November 2003 Section 6 Schematics ...
Page 182: ...Hydraulic Schematic 4WD Models after serial number 4460 November 2003 Section 6 Schematics ...