Operator's Manual
Seventh Edition · First Printing
Part No. 133083
Z-60/34
9
Work Area Safety
Electrocution Hazards
This machine is not
electrically insulated
and will not provide
protection from contact
with or proximity to
electrical current.
Maintain safe
distances from
electrical power lines
and apparatus in
accordance with
applicable
governmental
regulations and the
following chart.
Line Voltage
Required Clearance
0 to 50KV
3.0 m
50 to 200KV
4.6 m
200 to 350KV
6.1 m
350 to 500KV
7.6 m
500 to 750KV
10.6 m
750 to 1000KV
13.7 m
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not use the machine as a ground for welding.
Do not operate the machine during lightning or
storms.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum platform capacity
227 kg
Maximum occupants
2
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will
reduce the rated platform capacity and must be
factored into the total platform load. See the decals
with the options.
If using accessories, read, understand and obey
the decals and instructions with the accessory.