Work Area Safety
10 Z-62/40
Part No. 1257653
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a minimum,
the required clearance
contained in the chart
below must be followed.
Line Voltage
Required Clearance
0 to 50KV
3.05 m
50 to 200KV
4.60 m
200 to 350KV
6.10 m
350 to 500KV
7.62 m
500 to 750KV
10.67 m
750 to 1000KV
13.72 m
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum platform capacity of the platform
extension.
Maximum platform capacity
227 kg
Maximum occupants
2
The weight of options and accessories, such as
pipe cradles, panel cradles and welders, will
reduce the rated platform capacity and must be
subtracted from the platform capacity. See the
decals with the options and accessories.
If using accessories, read, understand and obey
the decals, instructions and manuals with the
accessory.