Second Edition • First Printing
Operator's Manual
Work Area Safety
Part No. 1267884
S-80X 13
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a
minimum, the required
clearance contained in the
chart below must be
followed.
Line Voltage
Required Clearance
0 to 50KV
10 ft
3.05 m
50 to 200KV
15 ft
4.60 m
200 to 350KV
20 ft
6.10 m
350 to 500KV
25 ft
7.62 m
500 to 750KV
35 ft
10.67 m
750 to 1000KV
45 ft
13.72 m
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must not
touch or operate the
machine until energized
power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity for the
restricted or unrestricted range of motion.
Maximum platform capacity
Unrestricted range of motion
500 lbs
227 kg
Maximum occupants
2
Maximum platform capacity
Restricted range of motion
1000 lbs
454 kg
Maximum occupants
3
If the restricted range of motion is selected for the
maximum platform capacity, do not move the
platform into the unrestricted range of motion zone.
Do not exceed the selected maximum platform
capacity.
Do not attach a platform rated at 500 lbs / 227 kg
(unrestricted range of motion) or 1000 lbs / 454 kg
(restricted range of motion) to machines with any
other rated load. See the serial label for the
maximum rated load.