background image

 CAUTION 

Read and understand 

all warnings 

(Page 2 

of this document)

 before 

beginning installation.

Contents

Overview -

 Components .......................................................................................1

Overview -

 Planning ..............................................................................................1

PLEASE READ -

 Safety Information ....................................................................2

Section 1 -

 Hanging Unit ......................................................................................3

Section 2 -

 Operation............................................................................................3

Section 3 -

 Adjusting for Level or Center of Gravity ........................................4

Section 4 -

 Installing Projector ...........................................................................4

Section 5 -

 Attaching Universal Projector Mount to Projector Pan ..............4

Section 6 -

 Installing Optional Environmental Air Space Housing ...............5

Installing Optional Ceiling Trim Kit .............................................................................5

Section 7 -

 Installing Ceiling Closure .................................................................5

Section 8 -

 Connecting Controls to Data Cable Splitter Board  ....................6

Section 9 -

  Clearing and Resetting Show Position ..........................................6

Section 10 -

 Optional Delay Feature ...................................................................6

Section 11 -

 Electrical Connections ...................................................................7

Section 12 -

 Operation ..........................................................................................7

Section 13 -

 Testing Safety Limit Switches .......................................................7

Section 14 -

 Adjusting Limit Switches ...............................................................7

Section 15 -

 Wiring Schematic ............................................................................8

Section 16 -

 Dimensions ......................................................................................8

Overview -

 Components

Overview -

 Planning

1. 

Based on screen location and projector 

specifications, determine proper position for 

projector installation.

2. 

Confirm that there is adequate space for 

installation and operation. Minimum clearance 

above ceiling level varies according to height 

of projector, optional projector mounting 

bracket, optional ceiling closure and optional 

Environmental Housing.

3. 

Arrange to provide service access to the unit.

4. 

When installed with Environmental Air Space Housing 

unit is suitable for use in an environmental air space 

in accordance with Section 300.22

(C)

 of the National 

Electrical Code, and Section 2-128, 12-010

(3)

 and 12-100 

of the Canadian Electrical Code, Part 1, CSA C22.1.

5. 

Total capacity of lift including cables, closure, projector, 

and bracket:

As Soon As Lift Arrives

1. 

Open carton and inspect for damage. 

2. 

Locate the following parts:

A. 

The unit itself

B. 

 Controls

C. 

 Any optional equipment

SL4

132 LBS.

60KG

SL6

125 LBS.

56.7KG

SL8

118 LBS.

53.5KG

SL10

108 LBS.

49KG

SL12

100 LBS.

45.4KG

TOOLS REQUIRED

POWER DRILL

PENCIL

TAPE MEASURE

HARDWARE

 

(by others) 

LEVEL

PLIERS

HEX WRENCH

SCREWDRIVER

Draper, Inc.  |  411 S. Pearl St. Spiceland, IN 47385 

draperinc.com  |  765.987.7999  |  800.238.7999  

© 2022 All Rights Reserved 

FORM: ScissorLiftSL_Inst22

Scissor Lift SL

Ceiling-recessed video projector lift

INSTRUCTIONS

INSTALLATION & OPERATION

If you have any difficulties installing or servicing your  

Scissor Lift SL, call your dealer or Draper, Inc. 

Summary of Contents for SL

Page 1: ...stallation and operation Minimum clearance above ceiling level varies according to height of projector optional projector mounting bracket optional ceiling closure and optional Environmental Housing 3 Arrange to provide service access to the unit 4 When installed with Environmental Air Space Housing unit is suitable for use in an environmental air space in accordance with Section 300 22 C of the N...

Page 2: ...nstalled in environmental air space housing and optional ceiling closure the ALTERNATE wiring for up limit switch may be used see Alternate Wiring schematic on page 5 36 Custom products installations may not be reflected in this manual Call Draper Inc if you have questions about the installation of custom products or any questions about your installation Caution Before servicing unit disconnect ha...

Page 3: ...witch operate the lift in the up direction so the lift s control encoder will recognize it s home location Until you do this the Down function will not work You must also do this if the Scissor Lift ever loses or is disconnected from the power When unit is first operated be cautious If unit fails to operate properly press STOP and recheck electrical connections before proceeding Cycle unit down an...

Page 4: ... or back 6 Replace screws 7 Check level again If still not level repeat Section 3 Adjusting for Level or Center of Gravity 9 5mm 18 x 1 25mm hex head cap screws for attaching Lifting Cable Bar to Bottom Pan BOTTOM PAN PROJECTOR PAN LIFTING CABLE BAR 9 5mm 18 x 1 25mm hex head cap screws for attaching Lifting Cable Bar to Bottom Pan Section 4 Installing Projector Draper s optional Universal Project...

Page 5: ...iling tile it may be necessary to cut tile so overall dimensions are same as or slightly less than closure panel Place tile into trim frame Lay closure panel on top back side of ceiling tile and tighten screws to hold in place 2 If installing large closure attach brackets to bottom of projector plate 3 Attach 5 16 8mm threaded rods to slots in projector plate or brackets CAUTION Ensure nuts and bo...

Page 6: ...ow Position requires adjusting then the Delay Switch must be switched to OFF while adjusting the show position CAUTION Be sure all switches are in OFF position before adjusting limit switch Always be prepared to shut lift off manually when new adjustment is being tested Please refer to wiring diagram PLEASE NOTE If the Scissor Lift loses power the DOWN function will not work until you operate the ...

Page 7: ...urs use set screws on bottom of fabric roller brackets to compensate for shift and level projector plate Section 14 Adjusting Limit Switches Caution The maintenance service factory limit setting must not be adjusted to a lower position than the preset factory limit setting In addition Draper does not recommend setting show position at the maintenance service position PLEASE NOTE Changing the fully...

Page 8: ...8 243 8cm SL10 14 35 6cm 10 304 8cm SL12 16 46 6cm 12 365 8cm Section 16 Dimensions There are four sizes of closure See separate instructions for details and dims FRONT VIEW SIDE VIEW There are four sizes of closure See separate instructions for details and dims See Table A TOP VIEW 20 527 mm 20 508 mm 24 624 mm 20 524 mm 16 419 mm 22 583 mm 11 mm x 4 See Table A TOP VIEW 20 527 mm 20 508 mm 24 62...