Service and Repair Manual
October 2016
Boom Components
38
S-80 • S-85 • S-80X
Part No. 1269074
9
Slowly operate the overhead crane to apply
tension to the lifting straps. Do not attempt to
lift the machine with the overhead crane.
10 Locate and remove the counterweight
retaining fastener at the center of the
counterweight. Carefully lift the counterweight
upwards and remove the counterweight from
the machine. Set the counterweight on the
ground. Do not leave the counterweight
suspended above the ground.
Crushing hazard. The turntable
counterweight will fall if not
properly supported by the
overhead crane resulting in
death or serious injury. Keep
personnel away from the area
when removing the
counterweight.
11 Attach lifting straps from a 5 ton / 5000 kg
overhead crane to each end of the boom.
Support the boom. Do not apply any lifting
pressure.
12 Support and secure the rod end of the boom lift
cylinder to a second overhead crane or similar
lifting device.
13 Remove the lift cylinder rod-end pivot pin
retaining fasteners. Use a soft metal drift to
remove the pin.
Crushing hazard. The boom
could fall if not properly
supported when the lift cylinder
rod-end pivot pin is removed.
14 Using auxiliary power, activate the boom down
function so the cylinder will retract. Retract the
cylinder just enough until the rod end of the
cylinder will clear the mounting bracket on the
boom. Turn the machine off.
Crushing hazard. The boom lift
cylinder could fall if not properly
supported and secured to the
lifting device.
15 Using the overhead crane, carefully lower the
boom lift cylinder and allow it to rest on the
boom rest pad. Protect the cylinder rod from
damage.
16 Remove the boom end cover retaining
fasteners and remove the cover.
17 Tag, disconnect and plug the boom extension
cylinder hydraulic hoses. Cap the fittings on
the cylinder.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
18 Tag and disconnect the electrical connector for
the cable break limit switch.
19 Tag and disconnect all boom wire harness
electrical connectors located at the pivot end of
the boom.
Summary of Contents for S-80
Page 16: ......
Page 76: ...Service and Repair Manual October 2016 Manifolds 60 S 80 S 85 S 80X Part No 1269074 ...
Page 86: ...Service and Repair Manual October 2016 Manifolds 70 S 80 S 85 S 80X Part No 1269074 ...
Page 144: ...Service and Repair Manual October 2016 128 Continental TME27 Engine Harness ...
Page 147: ...October 2016 Service and Repair Manual 131 S 80X Ground Control Box Wiring Diagram ...
Page 148: ...Service and Repair Manual October 2016 132 Deutz TD2 9 L4 Engine Harness ...
Page 151: ...October 2016 Service and Repair Manual 135 Perkins 404F 22T Engine Harness ...
Page 289: ...October 2016 Service and Repair Manual 273 Continental Options Schematic ...
Page 292: ...Service and Repair Manual October 2016 276 Deutz and Perkins Options Schematic ...
Page 293: ...October 2016 Service and Repair Manual 277 Platform Level Cutout CTE Option ...
Page 296: ...Service and Repair Manual October 2016 280 12 kW Hydraulic Generator Wiring Diagram ...
Page 297: ...October 2016 Service and Repair Manual 281 12 kW Hydraulic Generator Electrical Schematic ...
Page 300: ...Service and Repair Manual October 2016 284 Belt Driven Generator Option ...
Page 301: ...October 2016 Service and Repair Manual 285 Hydraulic Schematic 2WD Models ...
Page 305: ......