Performance Specifications
Drive speed, maximum
Stowed position,
RT tires
40 ft / 7.9 - 8.5 sec
12.2 m / 7.9 - 8.5 sec
Stowed position,
High Flotation tires
40 ft / 11 - 13 sec
12.2 m / 11 - 13 sec
Raised or Extended
40 ft / 40 - 45 sec
12.2 m / 40 - 45 sec
Braking distance, maximum
High range on paved surface
6 ft / 1.8 m
Gradeability
Refer to Operator's Manual
Boom function speeds, maximum from platform
controls
Jib Boom up (S-85)
25 - 35 sec
Jib Boom down (S-85)
15 - 25 sec
Boom up (ANSI, CSA, models)
57 - 65 sec
Boom up (CE, AS models)
75 - 83 sec
Boom down (ANSI, CSA, models)
61 - 69 sec
Boom down (CE, AS models)
75 - 83 sec
Boom extend
59 - 67 sec
Boom retract
57 - 65 sec
Turntable rotate, (360°) fully stowed
95 - 103 sec
Turntable rotate, (360°) boom raised
or extended
210 - 250 sec
Platform rotate, 160°
8 - 12 sec
Platform level (10° range of motion)
ANSI, CSA
3 - 5 sec
Platform level (10° range of motion)
CE, AS
20 - 22 sec
For operational specifications, refer to the
Operator's Manual.
Hydraulic Oil Specifications
Hydraulic Fluid Specifications
Genie specifications require hydraulic oils which are
designed to give maximum protection to hydraulic
systems, have the ability to perform over a wide
temperature range, and the viscosity index should
exceed 140. They should provide excellent antiwear,
oxidation prevention, corrosion inhibition, seal
conditioning, and foam and aeration suppression
properties.
Cleanliness level,
minimum
ISO 15/13
Water content,
maximum
250 ppm
Recommended Hydraulic Fluid
Hydraulic oil type
Chevron Rando HD Premium
Viscosity grade
32
Viscosity index
200
Optional Hydraulic Fluids
Mineral based
Shell Tellus S2 V 32
Shell Tellus S2 V 46
Shell Tellus S4 VX 32 Shell
Shell Donax TG (Dexron III)
Chevron 5606A
Biodegradable
Petro Canada Environ MV 46
Fire resistant
UCON Hydrolube HP-5046
Note: Genie specifications require additional
equipment and special installation instructions for
the approved optional fluids. Consult Genie Product
Support before use.
Optional fluids may not have the
same hydraulic lifespan and
may result in component
damage.
Note: Extended machine operation can cause the
hydraulic fluid temperature to increase beyond it's
maximum allowable range. If the hydraulic fluid
temperature consistently exceeds 200°F / 90°C an
optional oil cooler may be required.
Summary of Contents for S-80
Page 16: ......
Page 76: ...Service and Repair Manual October 2016 Manifolds 60 S 80 S 85 S 80X Part No 1269074 ...
Page 86: ...Service and Repair Manual October 2016 Manifolds 70 S 80 S 85 S 80X Part No 1269074 ...
Page 144: ...Service and Repair Manual October 2016 128 Continental TME27 Engine Harness ...
Page 147: ...October 2016 Service and Repair Manual 131 S 80X Ground Control Box Wiring Diagram ...
Page 148: ...Service and Repair Manual October 2016 132 Deutz TD2 9 L4 Engine Harness ...
Page 151: ...October 2016 Service and Repair Manual 135 Perkins 404F 22T Engine Harness ...
Page 289: ...October 2016 Service and Repair Manual 273 Continental Options Schematic ...
Page 292: ...Service and Repair Manual October 2016 276 Deutz and Perkins Options Schematic ...
Page 293: ...October 2016 Service and Repair Manual 277 Platform Level Cutout CTE Option ...
Page 296: ...Service and Repair Manual October 2016 280 12 kW Hydraulic Generator Wiring Diagram ...
Page 297: ...October 2016 Service and Repair Manual 281 12 kW Hydraulic Generator Electrical Schematic ...
Page 300: ...Service and Repair Manual October 2016 284 Belt Driven Generator Option ...
Page 301: ...October 2016 Service and Repair Manual 285 Hydraulic Schematic 2WD Models ...
Page 305: ......