Operator's Manual Supplement
First Edition • First Printing
Introduction
2
Lift Guard™ Contact Alarm
Part No. 1293402GT
Introduction
Lift Guard Contact Alarm System
The Lift Guard Contact Alarm system is designed
to alert the operator, occupants and ground
personnel to a potential hazard when an
obstruction makes contact with the secondary
guarding system. Machine movement will be
interrupted, an audible alarm sounds and the
beacon lights flash.
After the contact alarm is activated, the operator
can acknowledge the hazard and continue
operating the machine. The operator must release
the function enable switch and return the joystick to
the center position. Functions will resume
operation at reduced speeds allowing the operator
to continue to raise or drive the machine. The
audible alarm and beacons will deactivate when
the red Emergency Stop button is pushed in to the
off position.
Danger
Failure to obey the instructions and
safety rules in this manual will result
in death or serious injury.
Note: These installation instructions only
apply to the Genie models listed on the
front cover.
Note: The Lift Guard Contact Alarm is not
approved for use on models equipped with
the narrow platform option.
Summary of Contents for Lift Guard GR-12
Page 22: ......