First Edition • First Printing
Operator's Manual Supplement
Installation
Instructions
Part No. 1293402GT
Lift Guard™ Contact Alarm
11
25 Connect the wiring in the junction box. Refer to
the
Wiring Diagram
appropriate for your
machine.
26 Install the AC power outlet. (if equipped)
27 Install the junction box cover set aside.
28 Route the contact alarm harness installed in
the junction box along the platform with the
platform controls harness. Secure with cable
ties. Refer to the
Platform Mounting Location
and Harness Routing
. Genie part number
28443GT.
29 Mount the contact alarm assembly to the
platform.
30 Connect the coil cord and jumper harness to
the contact alarm and the harness from the
junction box. Secure the harnesses to the
platform using the provided cables ties.
Note: Models with an extension deck. Secure the
bottom of the coil cord to the middle guard rail of
the platform. Secure the top of the coil cord to the
hole at the top of the door rail.
1 junction box
2 coil cord
3 jumper harness
4 contact alarm
31 Disconnect the platform controller from the
C4 connector at the ground controls and return
it to the platform. Connect it to the platform
harness.
32 Connect the C4 connector to the mast
harness.
33 Update the control system software (if
required). Refer to the
Software Update
section.
2
1
3
4
Summary of Contents for Lift Guard GR-12