system is powered down or other conditions occur, the elevator can work normally without being
affected by the above contact. Of course, we have taken multiple security measures at the same
time (such as using a highly reliable switching power supply, adding a clutter suppressor to the
input and output ports, using hardware watchdog technology, using highly reliable TCP/IP
communication, all communication The data is based on CRC check technology, etc.) to ensure
that the system will not drop and crash.
2.
Visitor mode:
2.2 Features
l
using RS485 communication, the longest distance can reach 1200m
l
Modular design, flexible configuration, easy to upgrade
l
Separate design by controller and card reader, high security
l
The main control board and card reader adopt RS485 and Wiegand communication
modes, and the choice is flexible.
l
Wiegand mode is compatible with multiple Wiegand readers on the market
l
With backup battery, data will not be lost when power is off, battery is available for 5
years
l
Normal mode, mutual access mode. The controller has several working states such as
sleep, safety, NO, and NC.
l
Programmable linkage control and programmable card reader protocol settings
l
Direct control of the status of each output relay
l
Relay action time and card interval can be set
l
With fire Alarm signal input interface, when the fire switch signal is activated, the
elevator system does not work, and the elevator returns to the original state (the fire signal
provided by the elevator company should be a passive dry contact signal)
l
The system supports offline operation (smart) and flexible networking.
l
Main functions: visitor function, mutual access function, call function
2.3 Specification
l
CPU: 32-bit microprocessor
l
Control floor: 16 floors (expandable to 128 floors)
l
Communication method: RS485, TCP/IP.
l
Communication rate: TCP/IP communication, rate 100M. RS485: 9600/4800, 1, 1, N
l
Inspection method: CRC-16
l
Storage event: 100,000
l
Support card: 30,000 sheets
l
Working voltage: 12VDC, 3A
Summary of Contents for LCM16-IP
Page 5: ...1 4 Diagram...
Page 6: ...l System wiring...
Page 11: ...2 5 socket define l PIN definition 0...
Page 14: ...GB 34 P 7 2 V J V E W 0E 0...
Page 29: ...3 Add permission in security groups...
Page 30: ...Also can set the floor level Direct floor and visit floor 3 Add permission in personal list...
Page 31: ...4 If you want to use visitor mode Aplease short IN10 and GND...
Page 32: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk...